Spray Prot Monitor - Toro multi-pro 1200 Operator's Manual

Turf sprayer
Hide thumbs Also See for multi-pro 1200:
Table of Contents

Advertisement

Anti-siphon Fill Receptacle
To the front of the tank cover is a hose receptacle with a
threaded fitting and a 90 degree barbed fitting which you
can direct toward the tank opening (Fig. 21). This
receptacle allows you to connect a water hose to it and fill
the tank with water without contaminating the hose with
the chemicals in the tank.
Spray Pro
Monitor
The Spray Pro monitor displays and monitors various
system performance data such as vehicle speed and
application rates. It does not control the application rate.
The monitor has an LCD screen that displays the data you
select, a selection dial, and 4 buttons for calibrating the
monitor (Fig. 22).
2
3
3
Figure 22
1. LCD screen
2. Selection dial
Selection Dial
The selection dial contains the following positions:
Speed
Displays the ground speed in miles per hour (if the
Units of Measure is set to US or TURF) or kilometers
per hour (if the Units of Measure is set to SI).
Units of Measure
Displays the current measurement unit selection as
follows:
1
3
3
3. Calibration buttons
20
– US (United States measuring system)
– SI (metric system)
– TURF (as US but the volumes are in US gallons per
1000 sq ft instead of US gallons per acre)
Application Rate
Displays the application rate in US gallons per acre
(US), liters pre hectare (SI), or US gallons per 1000 sq
ft (TURF).
Calibration Volume
Records the volume in US gallons (US and TURF) or
liters (SI) that you spray. Use this setting to calibrate
the flowmeter.
Flowmeter Calibration
Switches between the flowmeter calibration value and
the currently entered calibration value at 3 second
intervals. Use this setting to adjust the flowmeter
calibration.
Calibration Distance
Records the distance traveled in feet (US and TURF) or
meters (SI) when calibrating the flowmeter.
Speed Cal
Switches between the speed calibration value and the
currently entered calibration distance value at 3 second
intervals. Use this setting to adjust the speed sensor
calibration.
Width
Sets and displays the boom width. The default setting is
220 inches (460 cm). This is based on 4 nozzles on the
right and left booms and 3 on the center boom all
spaced 20 inches (50.8 cm) apart.
Buttons
The monitor has the following buttons:
[RESET]
Resets the Calibration Volume and Calibration Distance
display settings to 0.
[CAL]
Used to enter and exit the calibration mode.
[–]
Reduces values displayed on the screen during
calibration.
[+]
Increases values displayed on the screen during
calibration.