1.Select an empty power supply module bay on the rear of the switch. If the target bay is protected by
a blank power filler plate, remove the blank.
2.Insert the power supply module into the selected power‐supply bay and gently push it into the slot
until it latches. Each power supply module has a mechanical guide key to prevent you from inserting the
module incorrectly.
Engage Latch
3.Connect the power cord to the power supply module and to an appropriate universal grounded AC
power source.
4.Make sure that the power supply module's OK and AC LEDs are green.
Removing and Replacing a Fan Module
62
G8264 Installation Guide
To replace a hot‐swap power supply module, complete the following steps:
The rear panel of the G8264 has four bays for hot‐swap fan modules. Four active fan
modules are required for redundancy.
With active fan modules in all fan bays, if one fan fails, the switch will send an error
message and continue operation. You can then replace the failed fan without
powering off the switch or disrupting switch functions. If a second fan fails, the
switch will send another error message, write a log message to flash memory, and
shut down to prevent overheating.
For proper airflow when operating the switch with one empty fan bay (a
non‐redundant configuration), the empty fan bay must be closed with a blank fan
filler plate.