CHECK GAS PRESSURE and ELECTRICAL INSTALLATION – IPI
CHECK GAS PRESSURE – IPI
1. Check gas type. The gas supply must be the same as
stated on the appliance's rating decal. If the gas supply
is different from the fi replace, STOP! Do not install the
appliance. Contact your dealer immediately.
2. To facilitate easier installation, a 18" (610 mm) fl ex line
with manual shut-off valve has been provided with this
appliance. Install and attach 1/2" gas line onto shut-off
valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fi replace for leaks. Use a solution of 50/50 water and
soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 58. After taking pressure reading, be sure and
turn captured screw clockwise fi rmly to reseal. Do not
over torque. Check test points for gas leaks.

ELECTRICAL WIRING

General
1. This fi replace is equipped with an IPI control valve which
operates on 6 volts. The 6 volt DC adapter plugs into
the fi replace junction box A/C power supply.
2. The IPI system can also be operated without A/C power.
The system can run on four (4) "AA" batteries using the
optional battery backup for approximately six (6) months
under normal use.
Optional Accessories
This fi replace may be used with a wall switch, wall mounted
thermostat or IPI hand held remote control.
20306739
Figure 58 –
IPI Valve
Do not use open fl ame to check for gas
leaks.
Electrical connections should only
be performed by a qualified, licensed
electrician. Main power must be off when
connecting to main electrical power supply
or performing service. All wiring shall be
in compliance with all local, city and state
codes. The appliance, when installed, must
be electrically grounded in accordance with
local codes or in the absence of local codes,
with the National Electrical Code ANSI/NFPA
70 (latest edition) and Canadian Electrical
Code, CSA C22.1.
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CFDV Series Gas Fireplace
Pressure Inlet
FP3034
Pilot Adjust-
ment Screw
Pressure
Outlet
35