OPERATING INSTRUCTIONS – MILLIVOLT
LIGHTING PILOT FOR THE FIRST TIME
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
Never check for gas leak with open
fl ame!
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections
Pilot
Each joint or connection
The control has an interlock device that does not allow the lighting of the fi replace up to the
moment the safety device of the fl ame has not interrupted the gas fl ow. After that period of
time (when the magnet is closed), it is possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this
operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise
pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
20306739
Field made joints / gas shutoff valve
Factory made joints
All joints on valve and control body

LIGHTING PILOT

to
CFDV Series Gas Fireplace
If using a soap and water solution
to test for leaks, DO NOT spray
solution onto control body.
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
P I L
O T
Pilot Position
Continued on next page