Troubleshooting Table - Travis Industries 864 HH Owner's Manual

Operation maintenance
Hide thumbs Also See for 864 HH:
Table of Contents

Advertisement

20

Troubleshooting Table

Problem:
Pilot Will Not Light
Main Burners Will
Not Start
Remote Control
Does Not Work
Thermostat Does
Not Work
Fireplace Will Not
Distribute Heat
Pilot Goes Out
Intermittently
Flames Are Too
Blue
Flames Are Too
Short (Under 6")
Thin Layer of Soot
Covers the Glass
© Travis Industries
Maintenance
Possible Cause:
A gas shut off valve is turned off
The gas control knob isn't turned to "PILOT"
The valve control knob isn't pushed in
The igniter wasn't pressed repeatedly
No Propane in Tank
The pilot light has gone out
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"
The remote control is not working correctly
The thermostat is disconnected or set too low
The pilot light has gone out
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"
The remote is too far away from the fireplace
The remote control receiver is turned "Off"
One of the two remote control batteries is dead
The pilot light has gone out
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"
The thermostat is set too low
The fireplace is not getting electricity
The fireplace is not up to temperature
The gas supply has been shut off
The fireplace has just been started
Improper air shutter adjustment
The flame height may be turned too low
The logs or coals are placed incorrectly
Improper air shutter adjustment
Check all gas shut off valves
See "Starting the Pilot Light" Step C
See "Starting the Pilot Light" Step C
See "Starting the Pilot Light" Step C
Check Tank Level
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
See the remote control instructions
See "Thermostat Operation"
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
Use the remote closer to the fireplace
See the remote control instructions
See the remote control instructions
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
See "Thermostat Operation"
Check the breaker switch
See "Operating Your Fireplace"
Keep the gas supply turned on
This is normal - see "Starting the
Fireplace for the First Time"
Adjust Air Shutter - contact your dealer
Turn the flame height to "HI" -
See "Adjusting the Flame Height"
See "Log Set Installation"
Adjust Air Shutter - contact your dealer
4080218
Don't Call for Service
Until You:
100-01181_003

Advertisement

Table of Contents
loading

This manual is also suitable for:

864 hh fireplace

Table of Contents