11 Electrical connection
Plug form A
(DIN EN 175301-803)
Fig. 2: Electrical connection of plug
1. Disconnect the plant from power supply.
2. Unscrew retaining screw 1.
3. Pull off plug 2 with terminal block 3 from solenoid.
4. Press terminal block 3 carefully out of plug 2.
5. Unscrew cable entry 6.
6. Remove pressure ring 4 and gasket 5.
7. Insert cable through cable entry 6, pressure ring 4, gasket
5 and plug 2.
8. Connect the cable.
9. Insert terminal block 3 again in the plug 2 until it audibly
clicks in position.
10. Screw plug 2 to solenoid with retaining screw 1 (max.
0.3 Nm).
11. Close cable entry 6.
Fig. 3: Rear of terminal block
Item
1
Supply voltage
2
Supply voltage
3
Not connected
Earth
GEMÜ 0326
6
4
5
1
2
3
Name

11.1 Plug design A

11.1.1 Without bridge rectifier (code 00, 01, 03, 05, 08, 09)
Control function 1 (NC), AC/DC voltage
control function 2 (NO), DC voltage
Solenoid valve
with plug form A
AC supply voltage:
DC supply voltage:
NC/NO valves
11.1.2 With bridge rectifier (code 06, 09)
Control function 2 (NO), AC voltage
Solenoid valve
with plug form A
AC supply voltage:
NO valves
11.1.2.1 ATEX version (DC version)
Solenoid housing
Blue
Brown
Green/yellow
11.1.2.2 ATEX version (AC version)
Brown
Blue
Green/yellow
14 / 20
Plug form A
L PE N
+ PE GND
Plug form A with bridge rectifier
L PE N
Solenoid housing