Field
Drop Unknown
Hub-Spoke
Flooding
Statistics
Input statistics
Output statistics
Gateway Interface
Tunnels
Link ID
State
Type
Flooding proxy
ACs
Link ID
Description
Action on source MAC-unknown frames received after the maximum number of
MAC entries is reached.
State of the hub-spoke function.
State of the VSI's flooding function:
Enabled—Flooding is enabled on the VSI. The VTEP floods unknown
unicast frames to both local and remote sites.
Disabled—Flooding is disabled on the VSI. The VTEP floods unknown
unicast frames only to local sites.
Packet statistics state:
Enabled—Packet statistics is enabled for the VSI.
Disabled—Packet statistics is disabled for the VSI.
Incoming traffic statistics:
Octets—Number of incoming bytes.
Packets—Number of incoming packets.
Errors—Number of error packets.
Discards—Number of discarded packets.
Outgoing traffic statistics:
Octets—Number of outgoing bytes.
Packets—Number of outgoing packets.
Errors—Number of error packets.
Discards—Number of discarded packets.
VSI interface name.
Information about the VXLAN tunnels assigned to the VXLAN.
Tunnel's link ID on the VSI.
Tunnel state:
Up—The tunnel is operating correctly.
Blocked—The tunnel is a backup proxy tunnel. Its tunnel interface is up, but
the tunnel is blocked because the primary proxy tunnel is operating correctly.
This value is available in Release 1138P01 and later versions.
Defect—The tunnel interface is up, but BFD cannot detect the remote VTEP.
This value is available in Release 1138P01 and later versions.
Down—The tunnel interface is down.
Tunnel assignment method:
Auto—The tunnel was automatically assigned to the VXLAN. For a
multicast-mode VXLAN, the tunnel (MTunnel) was automatically created and
assigned to the VXLAN to transmit flood traffic.
Manual—The tunnel was manually assigned to the VXLAN.
Flood proxy state:
Enabled—Flood proxy is enabled. The VTEP sends broadcast, multicast,
and unknown unicast traffic to a flood proxy server through the tunnel. The
flood proxy server replicates and forwards flood traffic to remote VTEPs.
Disabled—Flood proxy is disabled. The VTEP sends broadcast, multicast,
and unknown unicast traffic to remote VTEPs by using the unicast or
multicast mode.
This field is available in Release 1138P01 and later versions.
ACs that are bound to the VSI.
AC's link ID on the VSI.