H3C S12500-X Series Command Reference Manual page 18

Vxlan command reference
Hide thumbs Also See for S12500-X Series:
Table of Contents

Advertisement

Broadcast Restrain
Multicast Restrain
Unknown Unicast Restrain: -
MAC Learning
MAC Table Limit
Drop Unknown
Flooding
Statistics
Input statistics:
Octets
: 0
Packets
: 0
Errors
: 0
Discards : 0
Output statistics:
Octets
: 0
Packets
: 0
Errors
: 0
Discards : 0
Gateway Interface
VXLAN ID
Tunnels:
Tunnel Name
Tunnel1
Tunnel2
MTunnel0
ACs:
AC
FGE1/0/1 srv1000
Table 6 Command output
Field
VSI Description
VSI State
MTU
Bandwidth
Broadcast Restrain
Multicast Restrain
Unknown Unicast
Restrain
MAC Learning
MAC Table Limit
: -
: -
: Enabled
: -
: -
: Enabled
: Enabled
: VSI-interface 100
: 10
Link ID
State
0x5000001
Up
0x5000002
Up
0x6002710
Up
Link ID
0
Description
Description of the VSI. If the VSI does not have a description, the command does
not display this field.
VSI state:
Up—The VSI is up. A VSI is up only when its VXLAN has an up VXLAN
tunnel and an up AC.
Down—The VSI is down.
Administratively down—The VSI has been manually shut down by using
the shutdown command.
MTU on the VSI.
Maximum bandwidth in kbps on the VSI.
Broadcast restraint ratio.
Multicast restraint ratio.
Unknown unicast restraint ratio.
State of the MAC learning function.
Maximum number of MAC address entries on the VSI.
11
Type
Flooding proxy
Manual
Disabled
Manual
Disabled
Auto
Disabled
State
Up

Advertisement