CP 521
6.6.8
Transferring Parameter Setting Data (Job 90XX
The parameter setting data of the serial interface is stored on the memory
submodule in parameter blocks 0, 2 and 7 of data block (DB) 1. Configure the user
submodule before operation.
During operation, you can do the following with job number 90
Set new parameters for the serial interface (parameter block 0):
Job 9000
H
Set the XON/XOFF parameters (parameter block 2):
Job 9020
H
Set the operating mode and parameters (parameter block 7):
Job 9070
Print mode
H
9071
Transparent ASCII mode
H
9072
Interpretive ASCII mode
H
Operator inputs required:
Specify the parameters of the parameter block to be changed in bytes 2 to 7
Specify the number of the parameter block to be changed and the job in
byte 0.
Notes:
The "Transfer parameter setting data" job is more or less insignificant in print
mode since the configuration data for print mode is stored on the memory
submodule in DB 1.
A typical practical application would be if you want to replace a defective
printer at short notice by another printer whose interface must be differently
initialized.
The job does not change the contents of the memory submodule on the CP 521.
After warm restart, the CP uses the data of the memory submodule that is
plugged in.
See 7.3.1 for a more detailed description.