9.4
Supply Cord Replacement
The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It is
essential that prior to any disturbance of this internal wiring, all cable
routing and securing details are carefully noted to ensure re-assembly to
the same factory pattern is always maintained.
If the supply cord is to be changed or is damaged, it must be replaced with a special
cord assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Re-assemble to the same
pattern.
For information on cable connection consult the wiring diagram and cable gland fitting
instructions.
9.5
Cable Gland Fitting Instructions
To enable correct assembly of the cable gland the 'O'-ring must be placed over
the cable before the clamping insert can be tightened.
Note:
9.6
Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:
All models - HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for the
application and installed in accordance with the manufacturers instructions.
Cable diameter range:- 6.5 mm to 9.5 mm.
Figure 13
22
O ring
Clamping
insert