Sensorflow 21 compact mains water urinal flushing devices

Advertisement

Sensorflow 21 compact mains water
urinal flushing devices
A7001AA/GN, A7002AA/GN
40
Important:
1. Electrical connection: mains electric powered versions of these
products must be connected to a continuous permanent power supply.
2. Sensor protector: this black-out lens cover should only be removed
from the sensor after completing installation & at least 20 seconds
after powering up.
See page 4 for more details.
BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE
ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM
INSTALLER:
After installation please pass this instruction booklet to user
67
800
M33 x 1.5
max.30
IMPORTANT
INSTALLATION
INSTRUCTIONS
Ø15
61
Ø15

Advertisement

Table of Contents
loading

Summary of Contents for Armitage Shanks A7001AA/GN

  • Page 1 INSTALLATION Sensorflow 21 compact mains water INSTRUCTIONS urinal flushing devices A7001AA/GN, A7002AA/GN Ø15 Ø15 M33 x 1.5 max.30 Important: 1. Electrical connection: mains electric powered versions of these products must be connected to a continuous permanent power supply. 2. Sensor protector: this black-out lens cover should only be removed from the sensor after completing installation &...
  • Page 2: Table Of Contents

    TABLE OF CONTENT IMPORTANT PRE-INSTALLATION NOTES ........4 PRODUCT BOX CONTENTS ............5 SUPPLY CONDITIONS ..............6 WATER REGULATIONS ..................6 CATEGORIES OF RISK ..................6 URINAL PLUMBING ARRANGEMENTS ........6 INSTALLATION GUIDE ..............9 MOUNTING SENSORS ..................9 PLUMBING OVERVIEW ................... 10 ELECTRICAL CONNECTION ................
  • Page 4: Important Pre-Installation Notes

    IMPORTANT PRE-INSTALLATION NOTES MAINS ELECTRICAL POWER SUPPLY Mains powered Sensor Operated Products must be connected to a (fused / switched) continuous permanent power supply. Connection to an interrupted power supply intended to stop electrical consumption in an unused facil- ity, may adversely affect this sensor product and is therefore not recommended. Each time the power supply is reinstated the product briefly enters reprogramming mode.
  • Page 5: Product Box Contents

    PRODUCT BOX CONTENTS 1x Velcro pad set 1x Panel mount sensor 2x Couplers G 1/2“ female thread to 15 mm compression 1x Inline filter (mesh or strainer) Use with direct Use with auto cistern mains water supply and DC interrupter 1x Inline flow 1x Inline flow regulator...
  • Page 6: Supply Conditions

    Water regulations The fittings covered by this installation and maintenance instruction should be installed in accordance with the water regulations published in 1999*, therefore Armitage Shanks would strongly recommend that these fittings are installed by a professional installer *A guide to the Water Supply (Water Fittings) Regulations 1999 and the Water Byelaws 2000, Scotland is published by WRAS (Water Regulations Advisory Scheme) Fern Close, Pen-y-Fan Industrial Estate, Oakdale, Newport, NP11 3EH.
  • Page 7 URINAL PLUMBING ARRANGEMENTS continued… Direct mains water supply using box rim type urinal with AB air gap. Water is delivered to the solenoid valve which opens for a few seconds when triggered by the sensor. E621501 Jasper Morrison and E570101 Profile 21 box rim urinal are WRAS approved for use in UK. For standard urinal see next page.
  • Page 8 URINAL PLUMBING ARRANGEMENTS FOR STANDARD URINALS WITH MAINS WATER SUPPLY AND USE OF A DC PIPE INTERRUPTER Standard urinals that are used with mains water supply must use a recommended DC pipe Interrupter in accordance with EN 1717 up to category 5 for back-siphonage between solenoid valve and spreader as shown.
  • Page 9: Installation Guide

    INSTALLATION GUIDE Before connection, flush water through pipe-work to remove all debris etc. to prevent damage to the valve mechanism. THEN ENSURE WATER SUPPLIES HAVE BEEN ISOLATED. Mounting sensors SENSOR POSITIONING: we recommend the sensor be mounted approximately as illustrated on page 7.
  • Page 10: Plumbing Overview

    INSTALLATION GUIDE continued… Water supply pipe Ø 15mm Plumbing Overview copper Once the sensor has been secured to the panel or mounting surface, consideration should be given to installing & positioning of the solenoid valve. Two sets of standard 15 mm compression fit- Full ball tings are supplied for installing on either side isolation valve...
  • Page 11 INSTALLATION GUIDE continued… 5. Fit the pre-bended copper tube to either a urinal or to an auto cistern. 6. Slip the compression nut & olive onto the Ø15mm pre-bended tube and continue plumbing to the sole- noid valve using 15mm compression fitting supplied with this product.
  • Page 12 INSTALLATION GUIDE continued… Connecting copper pipe using compression fittings (General notes) • Ensure that the tube is cut square to the tube axis and is free from burs. • Ensure that the tube and fitting alignment is correct. • Carry out all pipe bending before making the joint. •...
  • Page 13: Electrical Connection

    INSTALLATION GUIDE continued… Electrical connection Connection of this product to mains power supply should be undertaken by black a competent person and should conform to IEE Wiring Regulations Orientation & position of solenoids, and PSU (Power Supply Unit) case can differ from installa- tion to installation.
  • Page 14 INSTALLATION GUIDE continued… Electrical connection continued… ENSURE MAINS POWER SUPPLY IS SWITCHED OFF BEFORE COMMENCING MAINS AC 13. Open the PSU case by unscrewing 4x PLUS LINK(S) posi-drive screws. 14. The lid & seal should separate from the PSU case. 15.
  • Page 15 Each type of PSU is identified by this coloured dot system: MAINS MAINS AC PLUS LINK(S) BLUE LINK MAINS AC -SOLO 230 V 24. Remove the pre-split grommet from the PSU lid. Slide the grey sensor cable into this grommet. 25.
  • Page 16 INSTALLATION GUIDE continued… Electrical connection continued… 28. Mains power cable (not supplied) should be flexible 3A rated (multi-strand) 2 core cable. Prepare the cable for connection into the PCB by carefully stripping back the outer sheath by about 100mm. Strip the wire ends back by about 5mm.
  • Page 17 INSTALLATION GUIDE continued… Electrical connection continued… A pair of self-adhesive Velcro-type pads are provided. Attach one to the side of the PSU case & the other to a suitable location on the rear of the mounting panel. Ensure the selected location does not stretch/stress the cables. Consid- eration should also be given to keeping the PSU case within easy reach/ access for maintenance staff.
  • Page 18: Urinal Operation

    INSTALLATION GUIDE continued… Electrical connection continued… (A7001..) (A7002..) (A7002..) Example above of a urinal installation where PSUs are all mains versions. URINAL OPERATION Sensorflow 21 products use an Infrared Sensor to activate the system. The sensor is triggered by something reflective (normally the user) in the Sensing Region.
  • Page 19: Sensor Ranging & Run Time Adjustment

    SENSOR RANGING & RUN TIME ADJUSTMENT (SENSOR SHOULD NOT BE LOCATED DIRECTLY OPPOSITE A WALL MIRROR.) The sensing range & run time can both be adjusted. Default factory settings are 400mm range & 4 seconds run time. Run time of 4 to 10 secs is considered satisfactory for most applications. Too short a run time will reduce the frequency at which an auto cistern flushes.
  • Page 20: Extension Cables

    SENSOR RANGING & RUN TIME ADJUSTMENT continued… B. Remote sensor programming unit is a hand held unit which can be used to change sensor range & other functions if required. Detailed instructions for using this unit are provided with the unit. (This unit can be purchased separately, for spares code see section 11).
  • Page 21: Hygiene Flush (Automatic)

    Maintenance continued… • Remove the 3 screws holding the coil. • Lift off the coil assembly. • Locate the diaphragm (inside the valve body). • Clean out the pilot hole(s) – use a thin gauge fuse wire (or similar). If diaphragm is damaged it should be replaced. •...
  • Page 22: Cleaning Chrome Surfaces

    Maintenance continued… A brief summary of how to navigate the programming unit is as follows: Hand unit ON Navigate to Menu 4 PARAMETER SENSOR 2013 (Enter) MENU 4.4 URINAL (Enter) AUTO-RINSE FREQUENCY: OFF ARROW UP (To required Delay time) (Enter). Recommended: 6 or 12 hours. AUTO-RINSE DURATION: (15 sec default) ARROW UP or DOWN (To required Run Time).
  • Page 23: Spare Parts

    SPARE PARTS For more information on spare parts why not visit our spare website: fast www.fastpart-spares.co.uk. Or contact customer care...
  • Page 24 0870 122 8822 This right is therefore reserved to vary specification without notice. AFTER SALES NON RESIDENTIAL FAX 0870 122 8282 Armitage Shanks is a division of Ideal Standard (UK) Ltd E-MAIL Armitage Shanks aftersalesnonresidential@idealstandard.com The Bathroom Works, National Avenue...