Sensorflow 21 shower – panel mount
A4168AA, A4185AA & A4186AA
Ø15
86
Ø15
Important:
1. Electrical connection: mains electric powered versions of these
products must be connected to a continuous permanent power supply.
2. Sensor protector: this black-out lens cover should only be removed
from the sensor after completing installation & at least 20 seconds
after powering up.
See page 3 for more details.
BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE
ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM
INSTALLER:
After installation please pass this instruction booklet to user
750
M33 x 1.5
max.30
Ø15
61
103
Ø15
IMPORTANT
INSTALLATION
INSTRUCTIONS
Ø48
3
40
116
67

Advertisement

Table of Contents
loading

Summary of Contents for Armitage Shanks Sensorflow 21 A4168AA

  • Page 1 INSTALLATION Sensorflow 21 shower – panel mount INSTRUCTIONS A4168AA, A4185AA & A4186AA M33 x 1.5 Ø48 max.30 Ø15 Ø15 Ø15 Ø15 Important: 1. Electrical connection: mains electric powered versions of these products must be connected to a continuous permanent power supply. 2.
  • Page 2: Table Of Contents

    TABLE OF CONTENT IMPORTANT PRE-INSTALLATION NOTES ........3 PRODUCT BOX CONTENTS ............4 SUPPLY CONDITIONS ..............5 WATER REGULATIONS ..............5 INSTALLATION GUIDE ..............6 MOUNTING THE SENSORS ................7 PLUMBING OVERVIEW ..................8 ELECTRICAL CONNECTION ................10 SHOWER OPERATION ..............16 SENSOR RANGING &...
  • Page 3: Important Pre-Installation Notes

    IMPORTANT PRE-INSTALLATION NOTES MAINS ELECTRICAL POWER SUPPLY Mains powered Sensor Operated Products must be connected to a (fused / switched) continuous permanent power supply. Connection to an interrupted power supply intended to stop electrical consumption in an unused facil- ity, may adversely affect this sensor product and is therefore not recommended. Each time the power supply is reinstated the product briefly enters reprogramming mode.
  • Page 4: Product Box Contents

    PRODUCT BOX CONTENTS 1x Panel mount sensor 2x Couplers G 1/2“ female thread to 15 mm compression 1x Velcro pad set 1x Inline 1x Solenoid 1x Extension service valve valve lead 2M. For with filter solenoid valve Each type of PSU is identified by this coloured dot system: MAINS...
  • Page 5: Supply Conditions

    WATER REGULATIONS The fittings covered by this installation and maintenance instruction should be installed in accordance with the water regulations published in 1999*, therefore Armitage Shanks would strongly recommend that these fittings are installed by a professional installer *A guide to the Water Supply (Water Fittings) Regulations 1999 and the Water Byelaws 2000, Scotland is published by WRAS (Water Regulations Advisory Scheme) Fern Close, Pen-y-Fan Industrial Estate, Oakdale, Newport, NP11 3EH.
  • Page 6: Installation Guide

    INSTALLATION GUIDE SENSOR POSITIONING: An example of a typical sensor operated shower installation is shown here. IMPORTANT: We recommend the sen- sor be positioned to one side of the shower outlet & within easy reach of the user. AVOID positioning the sensor directly beneath the shower outlet.
  • Page 7: Mounting The Sensors

    INSTALLATION GUIDE continued… Before connection, flush water through pipe-work to remove all debris etc. to prevent damage to the valve mechanism. THEN ENSURE WATER SUPPLIES HAVE BEEN ISOLATED. Mounting the sensors SENSOR POSITIONING: we recommend the sensor be mounted approximately as illustrated in figure 5a.
  • Page 8: Plumbing Overview

    INSTALLATION GUIDE continued… Outlet pipe to shower head Elbow to outlet Plumbing Overview (not supplied) Once the sensor has been secured to the panel, consideration should be given to in- stalling & positioning of the inline valve. In the plumbing installation water is being supplied from above (ceiling), but can be from any direction.
  • Page 9 INSTALLATION GUIDE continued… Outlet pipe to 6 & 8. To fit solenoid valve: shower head The couplers can be screwed onto both sides of the in-line solenoid valve. Ensure the seals provided are fitted as shown. Make good the joints, taking care not to use excessive force. Tighten with an adjustable spanner (25mm A/F).
  • Page 10: Electrical Connection

    INSTALLATION GUIDE continued… Electrical connection Connection of this product to mains power supply should be undertaken by black a competent person and should conform to IEE Wiring Regulations Orientation & position of solenoids, and PSU (Power Supply Unit) case can differ from installa- tion to installation.
  • Page 11 Electrical information & approvals: Power: 6W Input voltage: 100V - 240V~ 50 - 60Hz Protection class: II DIN EN 60730-1: Type 1 Approval EU: EN 60950, EN 60335 Approval UL: UL 1310 Additional cable information: The two cables that emerge from the rear of the sensor both have nominal lengths of 750mm.
  • Page 12 INSTALLATION GUIDE continued… Electrical connection continued… ENSURE MAINS POWER SUPPLY IS SWITCHED OFF BEFORE COMMENCING MAINS AC 13. Open the PSU case by unscrewing 4x PLUS LINK(S) posi-drive screws. 14. The lid & seal should separate from the PSU case. 15.
  • Page 13 Each type of PSU is identified by this coloured dot system: MAINS MAINS AC PLUS LINK(S) BLUE LINK BATTERY GREEN MAINS AC -SOLO BATTERY -SOLO 6V Lithium CR-P2 GREEN 230 V 24. Remove the pre-split grommet from the PSU lid. Slide the grey sensor cable into this grommet.
  • Page 14 INSTALLATION GUIDE continued… Electrical connection continued… 28. Mains power cable (not supplied) should be flexible 3A rated (multi-strand) 2 core cable. Prepare the cable for connection into the PCB by carefully stripping back the outer sheath by about 100mm. Strip the wire ends back by about 5mm. PCB connection: the appropriate wires of the mains cable should connected to the appropriate termi- nal on the block.
  • Page 15 INSTALLATION GUIDE continued… Electrical connection continued… A pair of self-adhesive Velcro-type pads are provided. Attach one to the side of the PSU case & the other to a suitable location on the rear of the mounting panel. Ensure the selected location does not stretch/stress the cables. Consid- eration should also be given to keeping the PSU case within easy reach/ access for maintenance staff.
  • Page 16: Shower Operation

    INSTALLATION GUIDE continued… Electrical connection continued… Mains water supply Service 50Hz valve Solenoid 240V valve Mains Mains Mains 240V 240V 240V Ceiling Extension Shower leads used outlet Sensor Example above of a shower installation where PSUs are all mains versions. Sensor taps stickers: To complete the installation, 2 stickers are provided which can be stuck onto a wall or panel in close proximity to this product to advise the end user that this product sensor operated.
  • Page 17: Sensor Ranging & Run Time Adjustment

    SENSOR RANGING & RUN TIME ADJUSTMENT (SENSOR SHOULD NOT BE LOCATED DIRECTLY OPPOSITE A WALL MIRROR.) The sensing range & run time can both be adjusted. Default factory settings are 100mm range & 30 seconds run time. Run time of 30 is considered satisfactory for most applications. Too short a run time will increase the frequency of the user’s interactions with sensor.
  • Page 18: Extension Cables

    SENSOR RANGING & RUN TIME ADJUSTMENT continued… B. Remote sensor programming unit is a hand held unit which can be used to change sensor range & other functions if required. Detailed instructions for using this unit are provided with the unit. (This unit can be purchased separately, for spares code see section 11).
  • Page 19: Maintenance

    MAINTENANCE SOLENOID VALVE FLOW DIRN If water continues to flow when the valve should be off, and if the sensor is correctly ranged, then the solenoid valve may have debris lodged in the diaphragm pilot hole or on the valve seat: •...
  • Page 20: Hygiene Flush (Automatic)

    Maintenance continued… Hygiene flush (Automatic) This hygiene flush is enabled on the urinal products and can be adjusted by the installer or maintenance staff using the optional remote programming unit (for part number see sect.11). The hygiene flush is used to combat periods of stagnation due to low usage of the product. The function activates the flush (or discharge to auto cistern) automatically if it hasn’t been used for a set time period. This function ensures regular movement of water combating bio film growth and bacteria colonisation. The programming unit should be held pointing towards the sen- sor at distance of approx. 100mm. Once enabled, this function will automatically turn the water on for a duration of 1 to 240 seconds if the product has not been used for a period of 6, 12, 24, 48, or 72 hours.
  • Page 21: Isolating Valve

    Isolating valve Isolation valve (supplied with this product) MUST be fitted to permit future maintenance of the product. A strainer (filter) is built into this valve. Isolation valve should be installed in an easily accessible location. strainer cap strainer screen isolating valve direction of flow When the isolator screw slot is parallel to the valve body, the valve is open & permits water to flow. To close the valve, rotate the isolator screw 90°. The filter can be checked & cleaned by unscrewing the cap using a 22mm A/F spanner. Expect some water to escape. The isolating valve can be closed to permit servicing of the solenoid valve, or to remove the product completely.
  • Page 22: Spare Parts

    SPARE PARTS FOR LONGER CABLE OPTIONS, REFER TO SECTION .8 For more information on spare parts why not visit our spare website: fast www.fastpart-spares.co.uk. Or contact customer care...
  • Page 23: Selection Of Our Fixed Shower Heads

    SELECTION OF OUR FIXED SHOWER HEADS B9436AA Idealrain S1 Rainshower with angled arm & swivel Shower Head B9437AA Idealrain M1 & L1 Rainshower with wall arm & swivel shower head B9441AA Idealrain M1 & L1 Rainshower with ceiling arm & swivel shower head B0024AA Idealrain Cube M1 &...
  • Page 24 0870 122 8822 This right is therefore reserved to vary specification without notice. AFTER SALES NON RESIDENTIAL FAX 0870 122 8282 Armitage Shanks is a division of Ideal Standard (UK) Ltd E-MAIL Armitage Shanks aftersalesnonresidential@idealstandard.com The Bathroom Works, National Avenue...