Armitage Shanks A4122AA Installation Instructions Manual

Armitage Shanks A4122AA Installation Instructions Manual

Sensorflow 21 standard & compact basin spouts

Advertisement

Sensorflow 21 standard & compact basin
spouts A4122AA, A4171AA, A4172AA,
A4664AA, A4798AA & A4799AA
Ø57
Ø10
750
Note:
Standard spouts
are 30mm taller than
the compact versions.
Important:
1. Electrical connection: mains electric powered version of this
product must be connected to a continuous permanent power supply.
2. Sensor protector: this black-out lens cover should only be removed from
the sensor after completing installation & at least 20 seconds after powering up.
See page 3 for more details.
BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE
ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM
INSTALLER:
After installation please pass this instruction booklet to user
15°
112
35 max.
Ø35
260
IMPORTANT
Ø15
103
Ø15
40
116
INSTALLATION
INSTRUCTIONS
61
67
86
Ø15
Ø15

Advertisement

Table of Contents
loading

Summary of Contents for Armitage Shanks A4122AA

  • Page 1 Sensorflow 21 standard & compact basin INSTALLATION spouts A4122AA, A4171AA, A4172AA, INSTRUCTIONS A4664AA, A4798AA & A4799AA Ø15 15° Ø57 Ø15 35 max. Ø15 Ø35 Ø10 Note: Standard spouts are 30mm taller than Ø15 the compact versions. Important: 1. Electrical connection: mains electric powered version of this product must be connected to a continuous permanent power supply.
  • Page 2: Table Of Contents

    & independent battery powered units: A4171AA (S) & A4798AA (C) supplied with mains power unit A4172AA (S) & A4799AA (C) supplied with link unit (up to 5 per A4171AA or A4798AA) A4122AA (S) & A4664AA (C) supplied with battery unit...
  • Page 3: Important Pre-Installation Notes

    IMPORTANT PRE-INSTALLATION NOTES MAINS ELECTRICAL POWER SUPPLY Mains powered Sensor Operated Products must be connected to a (fused / switched) continuous permanent power supply. Connection to an interrupted power supply intended to stop electrical consumption in an unused facil- ity, may adversely affect this sensor product and is therefore not recommended. Each time the power supply is reinstated the product briefly enters reprogramming mode.
  • Page 4: Product Box Contents

    PRODUCT BOX CONTENTS 1x Sensorflow 21 standard or 2x Couplers compact basin G 1/2“ female spout with thread to integral sensor 15 mm compression Regulated PCA outlet pre-fitted. See section 8 1x Spout mounting kit 1x Inlet adaptor 15 to 8mm compression 1x Outlet key 1x Flow...
  • Page 5: Supply Conditions

    WATER REGULATIONS The fittings covered by this installation and maintenance instruction should be installed in accordance with the water regulations published in 1999*, therefore Armitage Shanks would strongly recommend that these fittings are installed by a professional installer *A guide to the Water Supply (Water Fittings) Regulations 1999 and the Water Byelaws 2000, Scotland is published by WRAS (Water Regulations Advisory Scheme) Fern Close, Pen-y-Fan Industrial Estate, Oakdale, Newport, NP11 3EH.
  • Page 6: Installation Guide

    INSTALLATION GUIDE Before connection, flush water through pipe-work to remove all debris etc. to prevent damage to the valve mechanism. THEN ENSURE WATER SUPPLIES HAVE BEEN ISOLATED. Mounting 1. Remove the spout mounting kit if already assembled to the spout tail. Ensure the basin rubber washer (smaller diameter one) is in place as shown.
  • Page 7: Plumbing Overview

    INSTALLATION GUIDE continued… Spout inlet pipe Ø 10mm Plumbing Overview Inlet adaptor Once the spout has been secured to the ba- 15 to 10mm sin, consideration should be given to install- compression ing & positioning of the inline valves. A typical plumbing installation example is shown here.
  • Page 8 INSTALLATION GUIDE continued… 5. To fit inlet adaptor cont: Slip the larger compression nut & olive onto a short length of Ø15mm supply pipe. Push the supply pipe into the adaptor up to the shoulder. Slide the olive up to the adaptor &...
  • Page 9: Electrical Connection

    INSTALLATION GUIDE continued… Electrical connection Connection of this product to mains power supply should be undertaken by a competent person and should conform to IEE Wiring Regulations black Orientation & position of solenoids, and PSU (Power Supply Unit) case can differ from installa- tion to installation.
  • Page 10 INSTALLATION GUIDE continued… Electrical connection continued… ENSURE MAINS POWER SUPPLY IS SWITCHED OFF BEFORE COMMENCING MAINS AC 13. Open the PSU case by unscrewing 4x PLUS LINK(S) posi-drive screws. 14. The lid & seal should separate from the PSU case. 15.
  • Page 11 Each type of PSU is identified by this coloured dot system: MAINS MAINS AC PLUS LINK(S) BLUE LINK BATTERY GREEN MAINS AC -SOLO BATTERY -SOLO 6V Lithium CR-P2 GREEN 230 V 24. Remove the pre-split grommet from the PSU lid. Slide the grey sensor cable into this grommet.
  • Page 12 INSTALLATION GUIDE continued… Electrical connection continued… 28. Mains power cable (not supplied) should be flexible 3A rated (multi-strand) 2 core cable. Prepare the cable for connection into the PCB by carefully stripping back the outer sheath by about 100mm. Strip the wire ends back by about 5mm.
  • Page 13 INSTALLATION GUIDE continued… Electrical connection continued… A pair of self-adhesive Velcro-type pads are provided. Attach one to the side of the PSU case & the other to a suitable location on the rear of the mounting panel. Ensure the selected location does not stretch/stress the cables.
  • Page 14: Tap Operation

    INSTALLATION GUIDE continued… Electrical connection continued… Example above of an installation where PSUs are all mains versions. Sensor taps stickers: To complete the installation, 2 stickers are provided which can be stuck onto a wall or panel in close proximity to this product to advise the end user that this product sensor operated.
  • Page 15: Sensor Ranging

    SENSOR RANGING If the Sensor detects a strong reflection (or similar), the spout will turn on and off intermittently with no one present (Pulsing On / Off). In the unlikely event that this does happen, the Sensing Range must be reduced. This can be done using one of two ways: (A) manually or by (B) using a remote sensor programming unit.
  • Page 16: Outlet Options

    OUTLET OPTIONS This product comes with two outlets one fitted & the second supplied in a bag. The product is factory fitted with a laminar PCA regulated outlet which is secured within an anti-vandal (AV) housing. Unregulated full-flow flow straightener 0.5 bar l/min (SUPPLIED LOOSE)
  • Page 17: Hygiene Flush (Automatic)

    Maintenance continued… • Remove the 3 screws holding the coil. • Lift off the coil assembly. • Locate the diaphragm (inside the valve body). • Clean out the pilot hole(s) – use a thin gauge fuse wire (or similar). If diaphragm is damaged it should be replaced. •...
  • Page 18: Isolating Valve

    Maintenance continued… A brief summary of how to navigate the programming unit is as follows: Hand unit ON Navigate to Menu 4 PARAMETER SENSOR 2013 (Enter) MENU 4.1 HAND-WASH (Enter) AUTO-RINSE FREQUENCY: OFF ARROW UP (To required Delay time) (Enter). Recommended: 6 or 12 hours. AUTO-RINSE DURATION: (15 seconds default) ARROW UP or DOWN (To required Run Time).
  • Page 19: Spare Parts

    SPARE PARTS A 961 335 NU A 960 486 NU Fixing kit O-ring For more information on spare parts why not visit our spare website: fast www.fastpart-spares.co.uk. Or contact customer care...
  • Page 20: Cleaning Chrome Surfaces

    0870 122 8822 This right is therefore reserved to vary specification without notice. AFTER SALES NON RESIDENTIAL FAX 0870 122 8282 Armitage Shanks is a division of Ideal Standard (UK) Ltd E-MAIL Armitage Shanks aftersalesnonresidential@idealstandard.com The Bathroom Works, National Avenue...