Sensorflow 21 panel mounted
150 & 230 reach spouts with remote sensor
Ø30
G3/8
750
Ø25
Ø15
103
86
Ø15
Important:
1. Electrical connection: mains electric powered versions of these
products must be connected to a continuous permanent power supply.
2. Sensor protector: this black-out lens cover should only be removed
from the sensor after completing installation & at least 20 seconds
after powering up.
See page 3 for more details.
BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE
ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM
INSTALLER:
After installation please pass this instruction booklet to user
max.35
23
min.350
23
max.35
Ø15
61
Ø15
IMPORTANT
Ø55
150 / 230
Ø55
40
116
INSTALLATION
INSTRUCTIONS
150 Reach:
A4126AA,
A4180AA &
A4181AA
67
230 Reach:
A4182AA,
A4183AA &
A4184AA

Advertisement

Table of Contents
loading

Summary of Contents for Armitage Shanks Sensorflow A4180

  • Page 1 INSTALLATION INSTRUCTIONS Sensorflow 21 panel mounted 150 & 230 reach spouts with remote sensor max.35 Ø30 G3/8 Ø55 min.350 150 / 230 150 Reach: 230 Reach: Ø55 A4126AA, A4182AA, Ø25 A4180AA & A4183AA & A4181AA A4184AA max.35 Ø15 Ø15 Ø15 Ø15 Important: 1.
  • Page 2: Table Of Contents

    TABLE OF CONTENT IMPORTANT PRE-INSTALLATION NOTES ........3 PRODUCT BOX CONTENTS ............4 SUPPLY CONDITIONS ..............5 WATER REGULATIONS ..............5 INSTALLATION GUIDE ..............6 MOUNTING ......................6 PLUMBING OVERVIEW ..................7 ELECTRICAL CONNECTION ................9 TAP OPERATION ................14 SENSOR RANGING ...............
  • Page 3: Important Pre-Installation Notes

    IMPORTANT PRE-INSTALLATION NOTES MAINS ELECTRICAL POWER SUPPLY Mains powered Sensor Operated Products must be connected to a (fused / switched) continuous permanent power supply. Connection to an interrupted power supply intended to stop electrical consumption in an unused facil- ity, may adversely affect this sensor product and is therefore not recommended. Each time the power supply is reinstated the product briefly enters reprogramming mode.
  • Page 4: Product Box Contents

    PRODUCT BOX CONTENTS 1x Sensorflow 21 compact spout with integral sensor 1x Sensor 1x copper inlet pipe 1x Inlet elbow 15 to 10mm compression 2x Couplers G 1/2“ female thread to 15 mm Regulated PCA compression outlet pre-fitted. See section 8 2x Spout mounting kit 1x Velcro 1x Outlet key...
  • Page 5: Supply Conditions

    WATER REGULATIONS The fittings covered by this installation and maintenance instruction should be installed in accordance with the water regulations published in 1999*, therefore Armitage Shanks would strongly recommend that these fittings are installed by a professional installer *A guide to the Water Supply (Water Fittings) Regulations 1999 and the Water Byelaws 2000, Scotland is published by WRAS (Water Regulations Advisory Scheme) Unit 13, Willow Road, Pen-y-Fan Industrial Estate, Crumlin, Gwent, NP11 4EG.
  • Page 6: Installation Guide

    INSTALLATION GUIDE Before connection, flush water through pipe-work to remove all debris etc. to prevent damage to the valve mechanism. THEN ENSURE WATER SUPPLIES HAVE BEEN ISOLATED. Mounting DRILL PANEL HOLE Ø25 & Ø30 INSTALLATION HEIGHT: we recommend the spout outlet be positioned approximately 150-200mm above the basin or worktop (which ever is higher).
  • Page 7: Plumbing Overview

    INSTALLATION GUIDE continued… Spout inlet pipe Ø 10mm Inlet elbow 15 to 10mm Plumbing Overview compression Once the spout has been secured to the panel, consideration should be given to installing & positioning of the inline valves. A typical plumbing installation example is shown here.
  • Page 8 INSTALLATION GUIDE continued… 5. To fit inlet elbow cont: Slip the larger compression nut & olive onto a short length of Ø15mm supply pipe. Push the supply pipe into the elbow up to the shoulder. Slide the olive up to the elbow & tighten the compression nut with a 24mm A/F spanner.
  • Page 9: Electrical Connection

    INSTALLATION GUIDE continued… Electrical connection Connection of this product to mains power supply should be undertaken by a competent person and should conform to IEE Wiring Regulations black Orientation & position of solenoids, and PSU (Power Supply Unit) case can differ from in- stallation to installation.
  • Page 10 INSTALLATION GUIDE continued… Electrical connection continued… ENSURE MAINS POWER SUPPLY IS SWITCHED OFF BEFORE COMMENCING 13. Open the PSU case by unscrewing 4x MAINS AC posi-drive screws. PLUS LINK(S) 14. The lid & seal should separate from the PSU case. 15.
  • Page 11 Each type of PSU is identified by this coloured dot system: MAINS MAINS AC PLUS LINK(S) BLUE LINK BATTERY GREEN MAINS AC -SOLO BATTERY -SOLO 6V Lithium CR-P2 GREEN 230 V 24. Remove the pre-split grommet from the PSU lid. Slide the grey sensor cable into this grommet.
  • Page 12 INSTALLATION GUIDE continued… Electrical connection continued… 28. Mains power cable (not supplied) should be flexible 3A rated (multi-strand) 2 core cable. Prepare the cable for connection into the PCB by carefully stripping back the outer sheath by about 100mm. Strip the wire ends back by about 5mm.
  • Page 13 INSTALLATION GUIDE continued… Electrical connection continued… A pair of self-adhesive Velcro-type pads are provided. Attach one to the side of the PSU case & the other to a suitable location on the rear of the mounting panel. Ensure the selected location does not stretch/stress the cables.
  • Page 14: Tap Operation

    INSTALLATION GUIDE continued… Electrical connection continued… Example above of an installation where PSUs are all mains versions. Sensor taps stickers: To complete the installation, 2 stickers are provided which can be stuck onto a wall or panel in close proximity to this product to advise the end user that this product sensor operated.
  • Page 15: Sensor Ranging

    SENSOR RANGING If the Sensor detects a strong reflection (or similar), the spout will turn on and off intermittently with no one present (Pulsing On / Off). In the unlikely event that this does happen, the Sensing Range must be reduced.
  • Page 16: Outlet Options

    OUTLET OPTIONS This product comes with two outlets one fitted & the second supplied in a bag. The product is factory fitted with a laminar PCA regulated outlet which is secured within an anti-vandal (AV) housing. Unregulated full-flow flow straightener 0.5 bar l/min (SUPPLIED LOOSE)
  • Page 17: Hygiene Flush (Automatic)

    Maintenance continued… • Remove the 3 screws holding the coil. • Lift off the coil assembly. • Locate the diaphragm (inside the valve body). • Clean out the pilot hole(s) – use a thin gauge fuse wire (or similar). If diaphragm is damaged it should be replaced. •...
  • Page 18: Isolating Valve

    Maintenance continued… A brief summary of how to navigate the programming unit is as follows: Handunit ON Navigate to Menu 4 PARAMETER SENSOR 2013 (Enter) MENU 4.1 HAND-WASH (Enter) AUTO-RINSE FREQUENCY: OFF ARROW UP (To required Delay time) (Enter). Recommended: 6 or 12 hours. AUTO-RINSE DURATION: (15 sec default) ARROW UP or DOWN (To required Run Time).
  • Page 19: Spare Parts

    SPARE PARTS For more information on spare parts why not visit our spare website: fast www.fastpart-spares.co.uk. Or contact customer care...
  • Page 20: Cleaning Chrome Surfaces

    0870 122 8822 This right is therefore reserved to vary specification without notice. AFTER SALES NON RESIDENTIAL FAX 0870 122 8282 Armitage Shanks is a division of Ideal Standard (UK) Ltd E-MAIL Armitage Shanks aftersalesnonresidential@idealstandard.com The Bathroom Works, National Avenue...