DT9102 I4

Use supervisor
Code

Use supervisor
code

Use supervisor
code

Use supervisor
code
20220103-V0
Synchronisation time set (Synchron Time)
Here you can preset the synchronisation time for the remote
synchron function.
(The seconds are set to zero automatically.)
Synchrinisation puls width set (Synchron Gate Time Set)
Here you can set the pulse width of the remote
synchronisation signal. When the active state of the
synchron puls is lower then this value the instrument doesn't
accept it as a synchronisation puls.

E.g. when
to keep over 12 mA for more than 2 seconds to stop the
clock and activate the synchronisation after the loop current
goes under 8 mA.
1. digital output mode (Output 1)
Here you can set Out1 (terminal 1, 2) digital output mode.
Yuo can use it for synchrinising other clocks selecting the
repeater function.
2. digital output mode (Output 2)
Here you can set Out1 (terminal 3, 4) digital output mode.
Yuo can use it for synchrinising other clocks selecting the
repeater function.
is selected than the the loop current have