Function
Sequence of operations 1. Enter the menu by typing the supervisor code.
Exit from the menu item 1. After finishing the setting, press the MENU button, to exit
Exit from the menu
32
Digital output 1
7.9.
Out 1 digital output mode setting.
The way the code should be type in is described in Chapter
7.1. Typing the code (password) in. You see on the

display:
.
2. Keep stepping by pressing the ▲ button as long as you
see this menu item:
3. Enter the menu item by pressing the ENTER button.
4. You can read on the display
mnemonic is blinking.
5. Pressing the ENTER button you can read the active
digital output mode.
6. Press ▲ button to select the desired output mode:

= output in OFF state [Factory setting]

= repeating synchronisation input signal.
With this function you can synchronise an other DT9100 B
clock.

= output is in ON state.
from the menu item, and you see this:
(2. If you want to change the setting you have done just
now, or if you just want to check what you have typed in, go
on with the operation from point 3 of the Sequence of
operations.)
(3. If you don't want to exit the menu, as you want to do
further settings, then you may select the desired menu
items by pressing the ▲ button.)
1. Press the MENU button. First the mnemonic
(Save), then the mnemonic
display. With this the storing of the settings is completed.
The instrument has exited the menu and goes on with the
measurement.
(07. menu item)

.


(Exit) are shown on the
DT9102 I4
mnemonic. The

.

20220103-V0