17) Main Motor (50751)
Replacement Procedure:
▪
Unplug the unit.
▪
Make sure that there is no water in the unit.
▪
Remove the back panel (3 screws at the back)
▪
Remove the belt.
▪
Tilt the unit towards the left and carefully lay down the unit on the side.
▪
Unfix the four leveling legs and remove the bottom panel.
▪
The motor is supported with 3 bolts, unfix the same and replace the motor.
▪
Do the wiring as before / below.
▪
Fix all the parts back by following the reverse procedure.
Wiring: Main Motor
M4
4
M3
3
M2
2
M1
1
Testing Procedure:
▪
Cold Test:
1) Check the resistance between the following terminals, if the results match near about,
the motor is fine.
Sr. No
1
2
3
4
5
6
7
Please Note: Adjust the belt tension after replacing the motor.
8
M8
7
M7
6
M6
5
M5
Terminals
1 & 2
1 & 6
2 & 6
3 & 5
5 & 7
3 & 7
4 & 8
28
Holes for Bolts
Resistance
7.8 – 8.6
2.8 – 3.4
10.6 – 12.0
9.5 – 9.8
9.5 – 9.8
13.0 – 13.6
29.4 – 31.0