3) Pressure Switch (50774)
Replacement Procedure:
▪
Unplug the unit.
▪
Remove the top panel (Two screws behind and slide back)
▪
Unfix the screw to the pressure switch and replace the same.
▪
Fix all the parts back by following the reverse procedure.
Wiring: Pressure Switch – Back View
32 34 31 16 11 14 12
P1 P2 P3 P4 P5 P6 P7 P8 P9 P10
Testing Procedure:
▪
Cold Test:
1) Check for continuity between terminals 11 & 12, 21 & 22, 31 & 32.
2) If there is continuity between all the above stated terminals the pressure switch is good.
Please Note: The Pressure switch need to be checked with no water in the
unit.
22 24 21
14