6 LPG G30/31
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Marking on nozzle
Rated flow rate G30 (g/h)
Rated flow rate G31 (g/h)
7 Town Gas G110
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Marking on nozzle
The nozzles not provided are available at Authorised Service Centres.
Installation
AUX
SR
1.0
1.60
46
58
450
550
10
10
-
73
116
71
114
AUX
SR
1.0
1.6
130
165
400
500
OPEN
OPEN
H2
H3
RR
R
2.50
2.90
72
76
950
950
10
10
-
-
182
211
179
207
RR
R
2.5
2.9
220
245
900
900
4
4
H1
-
UR
3.50
85
1300
10
-
-
254
250
UR
3.4
280
1100
4
-
53