Execute the display hardware internal module interface-name interface-number status
command in probe view to collect the status information.
Execute the display hardware internal module interface-name interface-number reg 1
command in probe view to collect the FPGA information.
Execute the display hardware internal module interface-name interface-number reg 2
command in probe view to collect the MAC information.
Execute the display hardware internal module interface-name interface-number reg 3
command in probe view to collect the PHY information.
For interfaces on a FIP-300, FIP-310, or SAP-16EXP LPU, execute the display hardware
internal nae slot slot-number freein command in probe view to collect the hardware buffer
information.
For interfaces on a FIP-240 or SAP-4EXP LPU, execute the display hardware internal
dpaa slot slot-number bman pool-info command in probe view to collect the hardware
buffer information.
6.
Contact H3C Support.
Failure to forward packets
Symptom
An Ethernet interface on an intermediate router cannot forward packets.
Solution
To resolve the problem:
1.
Verify that the Ethernet interface can ping the directly connected device. If the ping operation
fails, see
2.
Use the debugging ip packet command to verify that the interface can transmit IP packets
correctly.
3.
If the problem persists, collect the following information for the interface:
Execute the display hardware internal module interface-name interface-number
statistics command in probe view to collect the interface statistics.
Execute the display hardware internal module interface-name interface-number status
command in probe view to collect the status information.
Execute the display hardware internal module interface-name interface-number reg 1
command in probe view to collect the FPGA information.
Execute the display hardware internal module interface-name interface-number reg 2
command in probe view to collect the MAC information.
Execute the display hardware internal module interface-name interface-number reg 3
command in probe view to collect the PHY information.
For interfaces on a FIP-300, FIP-310, or SAP-16EXP LPU, execute the display hardware
internal nae slot slot-number freein command in probe view to collect the hardware buffer
information.
For interfaces on a FIP-240 or SAP-4EXP LPU, execute the display hardware internal
dpaa slot slot-number bman pool-info command in probe view to collect the hardware
buffer information.
4.
Contact H3C Support.
"Failure to ping the directly connected
device."
31