Table of Contents

Advertisement

Quick Links

P/N 900124-00 REV. D 07/2018
A French manual is available upon request. Order
P/N 900184-00.
Ce manuel d'installation est disponible en
francais, s implement en faire la demande.
Numéro de la pièce 900184-00.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Ravenna™ CD
C
US
Report # 14-192
INSTALLATION AND OPERATION
MODELS
RDV CD
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900124-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RDV CD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IronStrike RDV CD

  • Page 1 Report # 14-192 Numéro de la pièce 900184-00. RDV CD This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 2 SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable Fireplace Insert chimenea All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    CONGRATULATIONS! Venting Installation ..........15 Vertical Venting ..........16 When you purchased your new gas fireplace insert, you joined Zero Clearance Fireplace Installation ......17 the ranks of thousands of individuals whose answer to their home Glass Door ............ 17-18 heating needs reflects their concern for aesthetics, efficiency and Firebox Liner Kit Installation (required accessory) ..
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions adicionales gratuitas. de sécurité supplémentaires gratuitement. IronStrike.us.com Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024 Note: English is red text on clear label. French and IronStrike.us.com...
  • Page 7: Installer - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions recibir etiquetas de instrucciones de seguridad de sécurité supplémentaires gratuitement. adicionales gratuitas. IronStrike.us.com Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024 Note: English is red text on clear label. French and IronStrike.us.com...
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     C AUTION: Hot while in operation. Do not touch. Severe Burns IMPORTANT SAFETY AND WARNING may result. Keep children, clothing furniture, gasoline and other INFORMATION liquids having flammable vapors away. ATTENTION: L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures graves. Surveiller les enfants.
  • Page 10: Orifice Size/Altitude Adjustment

    IMPORTANT: When installing these appliances into a factory ORIFICE SIZE/ALTITUDE ADJUSTMENT built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice (i.e.
  • Page 11: Codes And Approvals

    CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Certification These appliances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: Gas appliances must be tested and certified by a nationally recognized • Install this appliance in accordance with Massachusetts Rules and testing and certification laboratory to ANSI (American National Standard Regulations 248 C.M.R.
  • Page 12: Pre-Installation

    Only IHP conversion kits can be used to convert Copper Glass Media from NG to LP or LP to NG. Contact your IHP dealer for details. RATINGS RAVENNA CD (RDV CD) NATURAL GAS LP GAS Max/Min Input BTUh 0-2,000 Feet (0-610 M)u...
  • Page 13: Insert And Fireplace Dimensions

    31-1/4" 31-1/8 (794mm) O.D. = 2-15/16" (75mm) 15-7/8" 15-7/8 13-3/8" (403mm) 13-3/8 (340mm) Top View 15-7/8" 15-7/8 (403mm) 19-3/8" 19-3/8 (492mm) Right Side View Front View Left Side View Figure 2 - Insert Dimensions Minimum Fireplace Opening 31-1/2" (800mm) Front Opening Width 19-1/2”...
  • Page 14: Clearances To Combustibles

    Minimum Clearances to Combustibles 3"/77mm 3"/77mm Minimum clearances include any projections such as shelves, window RDV CD sills, mantels, spacers/standoffs or surfaces to combustible construction 3"/77mm etc. above the appliance. Paint or lacquer used to finish the mantel Facing and Mantel 1-1/2”...
  • Page 15: Fan Control Module Switch

    FAN CONTROL MODULE SWITCH INSTALLATION Before installation, verify the power switch on the Fan Control Module is Venting Installation in the ON position (as shown in Figure 6). Your IHP appliance must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, the current CAN/CGA B149.1 installation code).
  • Page 16: Vertical Venting

    Vertical Venting The existing fireplace chimneys The vent pipes must be connected to the proper collars on the unit and may take various contours the exhaust vent pipe must be connected to the termination cap or the which the flexible liners will unit will not operate.
  • Page 17: Zero Clearance Fireplace Installation

    Zero Clearance Fireplace Installation AVERTISSEMENT This appliance may be installed in a masonry or factory built/zero clear- Ne pas utiliser l'appareil si le panneau frontal en ance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. The verre n'est pas en place, est craqué...
  • Page 18: Firebox Liner Kit Installation (Required Accessory)

    Firebox Liner Kit Installation Instructions: 1. Remove the glass door following the instructions provided in this manual. 2. Remove the two brackets from the firebox using a 5/32" allen wrench (see Figure 11). Retain the screws for step 4, and discard the brackets as they will not be needed.
  • Page 19: Glass Media Installation (Required Accessory)

    Glass Media Installation Surround Installation The fireplace insert surround panels are made of heavy gage steel for Glass Media Kits (one required) durability and, if desired, for the ease of making an inside fit in the fire- place. See Packaging List for available sizes. Cat.
  • Page 20: Gas Line Installation

    Gas Line Installation Fuel Inlet Pressure Manifold Pressure Type Desired Minimum Maximum On Hi On Lo After leveling, position the insert in the fireplace - holding it about six Fire Fire inches out from its final location. Natural 7" WC 5"...
  • Page 21: Air Shutter Adjustment

    Air Shutter Adjustment Battery Backup - Battery Installation This appliance has an air shutter adjustment lever located behind the This appliance is equipped with a battery backup system. It requires four lower door of the inserts face, directly above the gas valve (see Figures (4) "AA"...
  • Page 22: Operation

    PI LO T See Page 36 for operating instructions. Unit-Mounted Controls Figure 20 - RDV CD IMPORTANT NOTE: When opening the lower door on the face while the insert is burning, pull at the far left or far right vent openings, because the door is hot during operation.
  • Page 23: Operation

    OPERATION - RDV CD Receiver Remote Control System REMOTE OFF The Remote and Receiver allows you to command the functions of your appliance from the comfort of your chair and is configured to control the On/Off primary burner operation, its flame levels (through six levels) and provides On/Off and Smart thermostatic control of the appliance.
  • Page 24 OPERATION - RDV CD Child Safety Lock-Out Transmission Low Battery Alarm Temperature Indicator Display Thermostat With the system in the “OFF” position, press the Thermostat Key and Room Temperature Off/On/Smart the Mode Key at the same time (see Figure 22). Look at the LCD screen...
  • Page 25: Flame Color And Behavior

    OPERATION - RDV CD Burner Flame Appearance Blower Speed Control Soot above Soot at No Soot at Flame Tip Flame Tip Flame Tip This appliance is equipped with a hot air circulating blower. The speed Dark Orange of the blower is controlled by the Remote. The blower speed can be...
  • Page 26: Wiring Diagrams

    N/C = NORMALLY CLOSED N/O = NORMALLY OPEN = FEMALE DISCONNECT Figure 27 - Electronic Control Schematic - Models RDV CD = MALE DISCONNECT = STUD CONNECTION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 27: Maintenance And Servicing

    o Check that the area around the insert is kept clear and is free of MAINTENANCE AND SERVICING combustible materials, gasoline and other flammable vapors and liquids. WARNING 2. The viewing glass should be cleaned periodically (see Glass Main- tenance). Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 28: Glass Maintenance

    Blower Removal Glass Door Cleaning and Maintenance Unplug the power supply cord from the electrical outlet prior to removing Cleaning: Do not remove or clean the glass door when hot. When cool, the blower. The blower can be accessed through the back wall of the firebox. the glass may be cleaned with a clean, soft cloth and a household glass cleaner.
  • Page 29: Replacing A Damaged Barrier

    Replacing A Damaged Barrier • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier Part No. J7510 (Contemporary Facade) or J7511 (Cast Pillar Facade). Follow installation instruc- tions.
  • Page 30: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 31: Replacement Parts

    RDV Blower Mounting Assembly H5752 Wire Grommet H8499 Firebox Door Assembly with Glass H8497 Hook and Loop Dot Kit - 4 sets H8856 RDV CD Burner Assembly H8651 TCC/CD Power Adaptor Box Assembly H8505 RDV TCC/CD Control Panel H8650 Convection Air Deflector H8482...
  • Page 32 REPLACEMENT PARTS - RAVENNA™ CD Facade Cast Pillar Facade Door NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 33: Accessories

    ACCESSORIES - RAVENNA™ CD Gas Conversion Product Reference Information Kits Cat. No. Description Ship. Ship. RDV33 Weight Volume H8854 RAVENNA CD 144 lb. 16.9 cu. ft. Cat. No. Model Description H8458 RDV-CK-TCC-LP to NG LP to NG Conversion Kit Porcelain Panel Kit H8858 RDV-CK-CD-NG to LP NG to LP Conversion Kit...
  • Page 34 Surround Trim Kits Pillar Cast Face Kits Note: 3 boxes to H5143 GFT2941-B Trim/Black 29" x 41" complete face H5145 GFT2948-B Trim/Black 29" x 48" 37-5/8" W x 23-3/4" H H5144 GFT3341-B Trim/Black 33" x 41" F2324 PILCST-GLASS-BARRIER Cast Door (Box 1 of 3) H5146 GFT3348-B Trim/Black 33"...
  • Page 35: Insert Labels

    (330mm) (254mm) (0mm) 3/8” (10mm) thick non-combustible *See owner’s manual for additional mantel clearances and options. or equivalent, with a k factor of .84. RATINGS Ravenna CD (RDV CD) For use only with barrier Part NATURAL GAS LP GAS No. J7510 (Contemporary...
  • Page 36 LIGHTING LABEL - RAVENNA™ CD FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. A.
  • Page 37: Warranty

    IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.
  • Page 38: Product Reference Information

    Normally, all parts should be ordered through your IHP distributor or Innovative Hearth Products dealer. Parts will be shipped at prevailing prices at time of order. 1769 East Lawrence Street Russellville, AL 35654 visit us at IronStrike.us.com Model Number _____________________________________________________ Serial Number _____________________________________________________ Date Installed ______________________________________________________ Your Dealer's Name _________________________________________________...

This manual is also suitable for:

P900124-00

Table of Contents