IronStrike VINTAGE VINT-DVS-U Installation And Operation Manual

Direct-vent

Advertisement

Quick Links

P/N 900137-00 REV. NC 01/2014
Ce manuel d'installation est disponible
en francais, s implement en faire la de-
mande. Numéro de la pièce 900187-00.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consulta-
tion ultérieure.
Direct-Vent
VINTAGE™
Portland
US
OTL Report No. 50-S-11b-5
P900137-00
AVERTISSEMENT

INSTALLATION AND OPERATION

MODELS
VINT-DVS-U
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d'incindie ou d'explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
SDVCS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VINTAGE VINT-DVS-U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IronStrike VINTAGE VINT-DVS-U

  • Page 1: Installation And Operation

    INSTALLATION AND OPERATION Direct-Vent VINTAGE™ Portland P/N 900137-00 REV. NC 01/2014 MODELS OTL Report No. 50-S-11b-5 Ce manuel d’installation est disponible en francais, s implement en faire la de- VINT-DVS-U SDVCS mande. Numéro de la pièce 900187-00. P900137-00 WARNING AVERTISSEMENT HOT GLASS WILL UNE SURFACE VITRÉE CHAUDE PEUT CAUSE BURNS.
  • Page 2: Table Of Contents

    CONGRATULATIONS! Horizontal Vent Installation ........13 Snorkel Terminations ..........14 When you purchased your new gas stove, you joined the ranks Vertical Vent Installation ........14 of thousands of individuals whose answer to their home heat- Flue Restrictors ..........15 ing needs reflects their concern for aesthetics, efficiency and our environment.
  • Page 3: Safety And Warning Information

    IMPORTANT SAFETY AND WARNING AVERTISSEMENT INFORMATION On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. WARNING WARNING Young children should be carefully supervised when they are in the same room as the appliance. Tod- Any safety screen or guard removed for servicing dlers, young children and others may be susceptible the appliance must be replaced prior to operating...
  • Page 4  T his appliance is only for use with the type of gas indicated on  F OR YOUR SAFETY do not install or operate this appliance without rating plate. This appliance is not convertible for use with other first reading and understanding this manual. Any installation or gases, unless a certified kit is used.
  • Page 5: Homeowner - Attaching Safety In Operation Warnings

    Cat. No. H8024 Replacement Label Kit recevoir gratuitement des étiquettes supplémentaires. Juego de etiquetas de repuesto - Nº de cat. H8024 Étiquettes de remplacement, n° cat. H8024 www.IronStrike.us.com www.IronStrike.us.com www.IronStrike.us.com NOTE: English is red text on clear label. French Nota: La etiqueta en inglés es transparente con texto and Spanish are white text on black label.
  • Page 6: Orifice Size/Altitude Adjustment

    ORIFICE SIZE/ALTITUDE ADJUSTMENT THE GAS STOVE For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice • Must conform with all local, state and national installation codes. In should be de-rated by 4% for every 1,000 feet to maintain the proper ratio the absence of local codes, the installation must conform with National of gas to air.
  • Page 7: Pre-Installation

    Millivolt Valve PRE-INSTALLATION This appliance is operated with a millivolt valve and therefore burns even during a power outage. Features Fuel Installation Options This appliance comes from the factory equipped to burn natural gas at a Residential specified elevation. The appliance can be converted to burn LP gas (liquid Vented vertical and horizontal propane) by changing the cassette (valve and pilot assembly) or installing Manufactured (mobile) home...
  • Page 8: Preparing Your Stove For Installation

    Dimensions Preparing Your Stove For Installation Read all instructions before beginning your installation. If instructions The gas line screws into the gas valve at the back of the stove 5” in from have not been read carefully, your installation could void your warranty the right side of the stove and 4-3/16”...
  • Page 9: Clearances To Combustibles

    Clearances to Combustibles Alcove dimensions Minimum clearances to combustible materials shown here are in inches The minimum width between alcove side walls is 30-1/2” (775mm). The (millimeters). See Pages 8 and 9 for pipe clearances. glass door lifts up to access the firebox on the stove. Therefore, if the stove is to be installed in an alcove, the alcove needs to be constructed to allow for removal of the glass door.
  • Page 10: Installation

    INSTALLATION Baffle and Log Set Installation Baffle The cast iron baffle is wrapped in foam and shipped between the outside of the firebox and the outer shell of the stove. Remove the foam and install the baffle in the rectangular hole in the top of the firebox. The baffle rests unsecured in the hole.
  • Page 11: Side Insert Installation

    Side-Insert Installation Follow these steps to install the cast iron inserts or your own custom stone inserts in this appliance: Upper Cast Piece Retainer 1. Remove the cast iron top and set it aside. 2. Remove the cast iron upper piece A - see Figure 14. Complete this step by unscrewing the (2) 5/32 hex-head screws labeled B in Figure 17.
  • Page 12: Vent Installation

    Vent Installation Minimum Components for Horizontal Installation: Horizontal Termination Kit which includes: Venting: This appliance has been tested and listed as a direct-vent heater system • 1 6-5/8”x 6” Black Pipe by OMNI-Test Laboratories, Portland, Oregon and is recommended for •...
  • Page 13: Vent Parts List

    Vent Parts List Horizontal Vent Installation Secure Vent ® direct-vent pipe by Security Chimneys* may be used with Venting terminals may not be recessed into a wall or siding. this appliance. Please see the lists below to verify the components avail- able from each direct-vent pipe manufacturer.
  • Page 14: Snorkel Terminations

    Snorkel Terminations For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall snorkel terminations are available. When using a snorkel, the stove can be vented directly out the back. There is a vent starter collar fastened to the stove (to vent straight out the back), remove Framed Hole: the four screws securing the collar, rotate the collar 180 degrees and 9-1/4”x 10-1/4”...
  • Page 15: Flue Restrictors

    Flue Restrictors 4 3 2 1 The flue restrictor settings shown in Figures 26 and 27 are for typical installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combustion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
  • Page 16: Horizontal Terminations

    Horizontal Terminations Vertical Terminations The shaded areas in the diagram below show all allowable combinations The diagram below shows all allowable combinations of straight verti- of vent configurations with horizontal terminations. Horizontal sections cal and offset to vertical vent configurations with vertical terminations. of pipe require 1/4”...
  • Page 17: Horizontal Vent Termination Locations

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 18: Gas Line Installation

    Gas Line Installation If the pressure is not sufficient, make sure the gas supply line is large enough, The supply regulator is properly adjusted and the total gas load for the residence does not exceed the amount supplied. This stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the Propane tanks are at pressures that will cause damage to valve com- current CAN/CGA B149.1 installation code).
  • Page 19: Operating Instructions

    Operating Instructions WHAT TO DO IF YOU SMELL GAS: • DO NOT try to light the appliance. Pre-Lighting Checklist • DO NOT touch any electric switch; do not use any phone in Be sure to check these items before the initial lighting of the your building.
  • Page 20: Flame Color And Behavior

    12. Adjust the flame height (and heat output) by turning the flame Flame Height Control Gas Control Knob height knob clockwise for full flame and counter- Knob (HI/LO) (Pilot / On / Off) clockwise for reduced flame. 13. Turn on the electric power to the appliance and set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
  • Page 21: Air Shutter Adjustment

    Air Shutter Adjustment If the optional blower is installed, the sound of rushing air may be heard when the blower is on. The blower sounds may be reduced by adjusting the speed control located on the blower assembly. Also, a slight clicking sound The air shutter control lever is located on the bottom of the stove directly may be heard as the gas valve or blower switch come on and off.
  • Page 22: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length “On-Off” Switch, Thermostat Or Remote Control 12 Gage 100 Feet Your stove comes equipped with an “On/Off” rocker switch used to turn 14 Gage 64 Feet the burner on and off while the pilot light is on. The switch is a round 16 Gage 40 Feet rocker switch located behind the main control panel door.
  • Page 23: Maintenance And Servicing

    The viewing glass should be cleaned periodically (see Glass Door MAINTENANCE AND SERVICING Cleaning and Maintenance). Should repairs or maintenance of the stove require the disassem- WARNING bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow Turn off gas and electrical power to the fireplace the instructions on Page 12 of this manual.
  • Page 24: Opening And Removing Door

    Glass Door pressure against the door. The latches need pulled forward and rotated at 90 degrees. Once the loops are in the receiving bracket you will then rotate them back 90 degrees so they are at the angle shown in Figure 36. WARNING Glass Door Cleaning And Maintenance •...
  • Page 25: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 26: Replacement Parts

    Contact an IHP dealer to obtain any of these parts. REPLACEMENT PARTS - VINT-DVS-U / SDVCS WARNING Cat. No. Description Never use substitute materials. Use of non-approved H6031 Cassette Assembly, NG (if LP, also requires 75190 parts can result in poor performance and safety haz- Conversion Kit) ards.
  • Page 27: Accessories

    ACCESSORIES - VINT-DVS-U / SDVCS Misc. Cat. No. Model Description 75194 VINT-TET BLWR Blower (ref. Form #775202M) Product Reference Information 75195 VINT-TETN-MHK Mobile Home Install Kit (ref. Form #775204M) Cat. No. Description Ship. Ship. 75203 VINT-RVTC Rear Vent Top Cover Weight Volume TSPK-B...
  • Page 28: Accessories

    ACCESSORIES - VINT-DVS-U / SDVCS Cost Effective Solution • Simple On/Off operation • Works with millivolt and low voltage electronic ignition controls Flame and Heat modulation Kit includes: • Includes solenoid for SIT millivolt valves Remote and Receiver • Thermostatic, manual or up to 9 hour Count- Thermostatic or Manual modes down Timer modes G-Fire Remote, Simple On/Off...
  • Page 29: Stove Labels

    SAFETY / LISTING LABEL - VINT-DVS-U / SDVCS Innovative Hearth Products LLC 1502 14th St. NW Auburn, WA., USA 98001 2014 2015 2016 2017 2011 2012 2013 2014 Part No./No. Pièce #36224 Rev. B, 02/2011 IGN 11-0831 LENNOX 11-0831 FRONT NOTE: DIAGRAMS &...
  • Page 30 LIGHTING LABEL - VINT-DVS-U / SDVCS Part No./No. Pièce #36224 Rev. B, 02/2011 IGN 11-0831 LENNOX 11-0831 BACK NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 31: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your IronStrike™ brand gas fireplace or insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 32: Product Reference Information

    See Page 26 for a complete replacement parts list. Use only parts sup- 1508 Elm Hill Pike, Suite 108 plied from the manufacturer. Nashville, TN 37210 visit us at www.IronStrike.us.com Model Number _____________________________________________________ Serial Number _____________________________________________________ Date Installed ______________________________________________________ Your Dealer's Name _________________________________________________...

This manual is also suitable for:

Vintage sdvcs

Table of Contents