IronStrike MPI32 Installation And Operation Manual

IronStrike MPI32 Installation And Operation Manual

Madison park series
Table of Contents

Advertisement

P/N 900288-00 REV. C 04/2016
A French manual is available upon request. Order
P/N 900289-00.
Ce manuel d'installation est disponible en
francais, s implement en faire la demande.
Numéro de la pièce 900289-00.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Madison Park™
C
US
Report # 14-098

INSTALLATION AND OPERATION

MODELS
MPI27
MPI32
MPI27CD
MPI32CD
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900288-00
MPI34
MPI34CD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPI32 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IronStrike MPI32

  • Page 1: Installation And Operation

    Report # 14-098 Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 900289-00. MPI27 MPI32 MPI34 MPI27CD MPI32CD MPI34CD This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Safety And Your Fireplace Insert

    SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable Fireplace Insert chimenea All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    Troubleshooting ............33 Insert Leveling ............ 14 Replacement Parts ............ 34-37 Installation .............. 16-21 Accessories ..............38 Light Bulb Installation (MPI32 and MPI34 models only) ... 16 Insert Labels ............39-45 Warranty ..............47 Product Reference Information .......... 48 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual.
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    Étiquettes de remplacement, n° cat. H8024 Cat. No. H8024 Replacement Label Kit Juego de etiquetas de repuesto - Nº de cat. H8024 IronStrike.us.com IronStrike.us.com IronStrike.us.com Remarque : Le texte anglais est rouge sur un support Note: English is red text on clear label. French and Nota: La etiqueta en inglés es transparente con texto...
  • Page 7: Installer - Attaching Safety In Operation Warnings

    Étiquettes de remplacement, n° cat. H8024 Cat. No. H8024 Replacement Label Kit Juego de etiquetas de repuesto - Nº de cat. H8024 IronStrike.us.com IronStrike.us.com Remarque : Le texte anglais est rouge sur un support IronStrike.us.com NOTE: English is red text on clear label. French transparent.
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     Plated surfaces must be cleaned with glass cleaner and a clean IMPORTANT SAFETY AND WARNING soft cloth before firing the first time or fingerprints will remain INFORMATION permanently. NEVER use brass polish to clean plated surfaces, this will remove the plating!!! ...
  • Page 10: Orifice Size/Altitude Adjustment

    • Has been certified for use with either natural gas or propane. • (Models MPI32, MPI32CD, MPI34 and MPI34CD ONLY) • Is NOT for use with solid fuels. • Is approved for sitting rooms and/or bedrooms.
  • Page 11: Codes And Approvals

    COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS WARNING These appliances are approved for installation in the US state of Mas- THIS FIREPLACE HAS BEEN ALTERED TO sachusetts if the following additional requirements are met: ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED •...
  • Page 12: Pre-Installation

    1 Insert Body 1 Log Set (Models MPI27, MPI32 and MPI34 Only) Installation Options 1 Bag of Embers (Models MPI27, MPI32 and MPI34 Only) Manufactured (Mobile) Home 1 Literature Package (installation and operation manual, warning labels, Natural Gas Or Propane (LP) pipe nipple, accent light bulb, batteries [3 AAA and 4 AA], short 'L' refractory panel brackets, remote control and hardware kit*).
  • Page 13: Insert And Fireplace Dimensions

    MPI27 and MPI27CD (454mm) (378mm) (276mm) (676mm) (425mm) (222mm) (365mm) (527mm) 19-3/8” 15-7/8” 11-7/8” 31-5/8” 21” 9-3/4” 15-3/8” 25-3/4” MPI32 and MPI32CD (492mm) (403mm) (302mm) (803mm) (533mm) (248mm) (391mm) (654mm) 23-7/8” 16-1/4” 12-1/4” 33-5/8” 23” 10” 19-7/8” 27-3/4” MPI34 and MPI34CD...
  • Page 14: Clearances To Combustibles

    D = Vertical Distance from base of appliance 0" 10" to Hearth Extension ......... (0mm) ( E = Minimum Horizontal Distance 2" 0” Non-Combustible from Front of Appliance......(51mm) (0mm) Figure 4 B - MPI32 and MPI32CD Clearances NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 15: Clearances To Combustibles

    MINIMUM CLEARANCES TO COMBUSTIBLE MPI34 / MPI34CD MINIMUM CLEARANCES A = Mantel ..........36" (914mm) B = Side Wall ..........4" (102mm) Mantel Mantel C = Mantel Depth ........... 10" (254mm) HEARTH PROTECTION D = Vertical Distance from base of appliance 0"...
  • Page 16: Installation

    INSTALLATION The liner connector plate can be removed (as shown in Figure 7) to make Light Bulb Installation - Models MPI32, MPI32CD, MPI34 and it easier to connect the flex liners to the intake and exhaust collars. Re- MPI34CD (refer to Figure 5) install the liner connector plate when the insert is placed in the fireplace.
  • Page 17: Vertical Venting

    Vertical Venting (see Figure 6) Flue Restrictor - Models MPI32, MPI32CD, MPI34 and MPI34CD The flue restrictor settings shown in Figure 8 are for typical installations The vent pipes must be connected to the proper collars on the unit and and are based upon laboratory testing.
  • Page 18: Firebox Liner Kit (Required Accessory)

    #8 x 3/8" Phillips screw provided with this manual (Figure 10). Figure 11 Log Installation for Traditional Models MPI32 and MPI34 If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in...
  • Page 19 6. Install the right log as shown in Figure 15. Both sides of the log are 2. Place a layer of glowing embers (rockwool) directly over the ports as pre-molded to fit onto the log rack. Rest rear of log on log support. shown in Figure 13.
  • Page 20 Log Installation for Traditional Model MPI27 If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas. The size and position of the log set is critical to achieve a safe, reliable and attractive flame pattern.
  • Page 21: Surround Panels Installation (Required Accessory)

    Surround Installation - All Models Facade Installation (required accessory) - All Models 1. Position the appliance in the fireplace, but a few inches in front of its A number of different facade styles are available for your appliance. See final location. the installation instructions packaged with your facade.
  • Page 22: Gas Line Installation

    Gas Line Installation The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of After leveling, position the insert in the fireplace - holding it about six the gas supply piping system at test pressures equal to or less than inches out from its final location.
  • Page 23: Air Shutter Adjustment

    Air Shutter Adjustment Battery Backup - Battery Installation This appliance has an air shutter control lever located behind the facade, This appliance is equipped with a battery backup system. It requires under the glass door (see Figure 24). The lever is linked to the primary air four (4) "AA"...
  • Page 24: Operating Instructions

    TO TURN OFF GAS TO APPLIANCE OPERATION 1. Turn the main power ON/OFF switch in the control compartment to Pre-Lighting Checklist "OFF." 2. Turn off all electric power to the appliance if service is to be performed. Be sure to check these items before the initial lighting of the insert: 3.
  • Page 25: Operation

    OPERATION - ALL MODELS Install 3 AAA type batteries in the Remote (transmitter) battery bay, located on the base of the Remote. With the batteries already installed in the Remote, push the ON button. The Receiver will “beep” three times Remote Control System to indicate the Remote’s command is accepted and sets to the particular code of that Remote.
  • Page 26 OPERATION - ALL MODELS Child Safety Lock-Out Transmission Low Battery Alarm Temperature Indicator Display Thermostat With the system in the “OFF” position, press the Thermostat Key and Room Temperature Off/On/Smart the Mode Key at the same time (see Figure 28). Look at the LCD screen SMART on the Remote to verify that a C or F is visible to the right of the Room Temperature display (see Figure 29).
  • Page 27: Blower Operation

    OPERATION - ALL MODELS Burner Flame Appearance Blower Speed Control Soot above Soot at No Soot at Flame Tip Flame Tip This appliance is equipped with a hot air circulating blower. The speed Flame Tip of the blower is controlled by the Remote. The blower speed can be Dark Orange Semi-Transparent adjusted through six (6) levels.
  • Page 28: Wiring Diagram

    ** Accent light not available for MPI27 or MPI27CD Figure 33 - Electronic Control Schematic - Models MPI27, MPI27CD, MPI32, MPI34CD, MPI34 AND MPI34CD CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 29: Maintenance And Servicing

    Figure 34 - Proper Pilot Flame Appearance S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé. Light Bulb Replacement - Models MPI32, MPI32CD, MPI34 and MAINTENANCE CHECKLIST MPI34CD (refer to Figure 35) The following should only be performed by a qualified service technician.
  • Page 30: Door Removal

    Glass Door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. See Detail A SEE DETAIL A • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 31: Glass Maintenance

    Glass Door Cleaning and Maintenance Cleaning: Do not remove or clean the glass door when hot. When cool, the glass may be cleaned with a clean, soft cloth and a household glass cleaner. For cleaning white condensation from the interior glass, use a gas fireplace glass cleaner available from your dealer.
  • Page 32: Replacing A Damaged Barrier

    • For models MPI27 and MPI27CD, use with barrier part number J4343. For models MPI32 and MPI32CD, use with barrier part number J4785. For models MPI34 and MPI34CD, use with barrier part number J5006. Follow installation instructions.
  • Page 33: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 34: Replacement Parts

    Contact an IHP dealer to obtain any of these parts. REPLACEMENT PARTS - MPI27 / MPI27CD WARNING Item # Cat. No. Description H9174 Fire Box Door Assembly with Glass Never use substitute materials. Use of non-approved Log Cassette Assy NG 30,000 BTU H9164 parts can result in poor performance and safety haz- (for LP add Kit H9163) - MPI27 only...
  • Page 35 REPLACEMENT PARTS - MPI27 / MPI27CD NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 36 Contact an IHP dealer to obtain any of REPLACEMENT PARTS - MPI32, MPI32CD, MPI34 AND MPI34CD these parts. MPI32 MPI32CD MPI34 MPI34CD Item # Description WARNING Firebox Door Assembly with Glass J7594 F2154 Never use substitute materials. Cassette Assembly NG 34,000 BTU...
  • Page 37: Replacement Parts

    REPLACEMENT PARTS - MPI32, MPI32CD, MPI34 AND MPI34CD NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 38: Accessories

    FP3846-4S-MPDVI27 4 Sided Surround Trimmable, H9123 80 lb. 12.22 cu. ft. Contemp 27, Small Insert 46"W x 38"H 3 Sided Surround, MPI32, Madison Park™ 32, F2296 112 lb. 18.17 cu. ft. F2307 FP4126-MPDVI32 Medium Insert 41" W x 26" H...
  • Page 39: Insert Labels

    SAFETY / LISTING LABEL - MPI27 SERIAL MODEL Madison Park™ 27 MPI27 MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 14-098 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
  • Page 40 SAFETY / LISTING LABEL - MPI27CD SERIAL MODEL Madison Park™ 27 CD MPI27CD MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS Report No. 14-098 1502 14TH ST NW AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
  • Page 41 SAFETY / LISTING LABEL - MPI32 SERIAL Madison Park™ 32 MODEL MPI32 MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 14-098 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
  • Page 42 SAFETY / LISTING LABEL - MPI32CD SERIAL MPI32CD MODEL Madison Park™ 32 CD MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 14-098 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 &...
  • Page 43 SAFETY / LISTING LABEL - MPI34 SERIAL MODEL Madison Park™ 34 MPI34 MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 14-098 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 &...
  • Page 44 SAFETY / LISTING LABEL - MPI34CD SERIAL MODEL Madison Park™ 34 CD MPI34CD MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 14-098 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 &...
  • Page 45 LIGHTING LABEL - MADISON PARK™ SERIES FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. A.
  • Page 46 NOTES...
  • Page 47: Year Limited Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IRONSTRIKE.US.COM.
  • Page 48: Product Reference Information

    Normally, all parts should be ordered through your IHP distributor or Nashville, TN 37210 dealer. Parts will be shipped at prevailing prices at time of order. visit us at IronStrike.us.com When ordering repair parts, always give the following information: Model Number _____________________________________________________...