Table of Contents

Advertisement

P/N 900125-00 REV. B 02/2016
A French manual is available upon request. Order
P/N 900185-00.
Ce manuel d'installation est disponible en
francais, s implement en faire la demande.
Numéro de la pièce 900185-00.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Ravenna™ IPI / TCC
C
US
Report # 14-192
This fireplace insert is factory equipped for 40,000 BTU input and can be converted to
33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas
or P/N H5925 for Propane Gas).

INSTALLATION AND OPERATION

MODELS
RDV33/40 IPI
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900125-00
RDV33/40 TCC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ravenna RDV33 IPI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IronStrike Ravenna RDV33 IPI

  • Page 1: Installation And Operation

    INSTALLATION AND OPERATION Direct-Vent Ravenna™ IPI / TCC P/N 900125-00 REV. B 02/2016 P900125-00 A French manual is available upon request. Order P/N 900185-00. MODELS Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 900185-00. Report # 14-192 RDV33/40 IPI RDV33/40 TCC...
  • Page 2 SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable Fireplace Insert chimenea All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    CONGRATULATIONS! Firebox Panel Kit (required accessory) ....17-18 Log Set Installation .......... 17-18 When you purchased your new gas fireplace insert, you joined Surround Panels Installation (required accessory) ..18 the ranks of thousands of individuals whose answer to their home Operating Options ..........
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions gratuitas. de sécurité supplémentaires gratuitement. IronStrike.us.com Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024 Note: English is red text on clear label. French and IronStrike.us.com...
  • Page 7: Installer - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions recibir etiquetas de instrucciones de seguridad de sécurité supplémentaires gratuitement. adicionales gratuitas. IronStrike.us.com Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024 NOTE: English is red text on clear label. French IronStrike.us.com...
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     Plated surfaces must be cleaned with glass cleaner and a clean IMPORTANT SAFETY AND WARNING soft cloth before firing the first time or fingerprints will remain INFORMATION permanently. NEVER use brass polish to clean plated surfaces, this will remove the plating!!!  C AUTION: Hot while in operation.
  • Page 10: Orifice Size/Altitude Adjustment

    IMPORTANT: When installing these appliances into a factory ORIFICE SIZE/ALTITUDE ADJUSTMENT built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice (i.e.
  • Page 11: Codes And Approvals

    CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Certification These appliances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: Gas appliances must be tested and certified by a nationally recognized • Install this appliance in accordance with Massachusetts Rules and testing and certification laboratory to ANSI (American National Standard Regulations 248 C.M.R.
  • Page 12: Pre-Installation

    Packaging List PRE-INSTALLATION Insert Body Packaging List Features 1 Insert Body Installation Options 1 Log Set Manufactured (Mobile) Home 1 Bag of Embers Natural Gas Or Propane (LP) 1 Power Cord Bedrooms 1 Fasteners: 6 slotted 1/4" truss screws Remote Control 6 speed nuts 9 spring clips Electrical...
  • Page 13: Insert And Fireplace Dimensions

    31-1/4" 31-1/8 (794mm) O.D. = 2-15/16" (75mm) 15-7/8" 15-7/8 13-3/8" (403mm) 13-3/8 (340mm) Top View 15-7/8" 15-7/8 (403mm) 19-3/8" 19-3/8 (492mm) Right Side View Front View Left Side View Figure 2 - Insert Dimensions Minimum Fireplace Opening 31-1/2" (800mm) Front Opening Width 19-1/2”...
  • Page 14: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES 3"/76mm IMPORTANT: If unit is converted to an RDV33 IPI/TCC from an 3"/76mm RDV40 IPI/TCC, the clearances to combustibles can be reduced 3"/76mm RDV40 IPI/TCC as shown on this page. 1-1/2” 38mm Facing and Mantel Side View WARNING: If this unit is ever converted back to an RDV40 IPI/ TCC, ensure that the clearances are correct for this model.
  • Page 15: Fan Control Module Switch (Rdv 33/40 Tcc Models Only)

    FAN CONTROL MODULE SWITCH INSTALLATION RDV33/40 TCC Models Only Venting Installation Before installation, verify the power switch on the Fan Control Module is in the ON position (as shown in Figure 6). Your IHP appliance must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, the current CAN/CGA B149.1 installation code).
  • Page 16 Vertical Venting The existing fireplace chimneys The vent pipes must be connected to the proper collars on the unit and may take various contours the exhaust vent pipe must be connected to the termination cap or the which the flexible liners will unit will not operate.
  • Page 17: Zero Clearance Fireplace Installation

    Zero Clearance Fireplace Installation Firebox Liner Kit and Log Set Installation This appliance may be installed in a masonry or factory built/zero clear- If logs are not installed according to the log installation instructions, ance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must flame impingement and improper combustion could occur and result in be removed and the ZC damper must be removed or secured open.
  • Page 18: Surround Panels Installation (Required Accessory)

    Top Log Figure 13 Ports Surround Installation The fireplace insert surround panels are made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fire- Figure 10 Side Firebox Panels place. See Packaging List for available sizes. 1.
  • Page 19: Operating Options

    - RDV33/40 IPI Models Only Operating Options OPTION 1 Burner ON/OFF Switch Installation: Surround The burner ON/OFF switch on your gas appliance is used to turn the burner Panel on and off. This switch can be installed in the hole in the right side of the top surround panel (see Option 1) or in the hole in the control panel in the control compartment (see Option 2).
  • Page 20: Gas Line Installation

    Gas Line Installation Inlet Pressure Manifold Pressure Fuel On Hi On Lo After leveling, position the insert in the fireplace - holding it about six Type Desired Minimum Maximum Fire Fire inches out from its final location. Natural 7" WC 5"...
  • Page 21: Air Shutter Adjustment

    Air Shutter Adjustment Battery Backup - Battery Installation This appliance has an air shutter control lever located behind the lower This appliance is equipped with a battery backup system. It requires four door on the insert's face and to the left of the gas valve (see Figures (4) "AA"...
  • Page 22: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN- A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. OPERATION WARNING LABELS B. BEFORE OPERATING smell all around the appliance area for gas. Be sure It is required that the set of safety instruction labels that have been to smell next to the floor because some gas is heavier than air and will furnished with the appliance be affixed to the operation and control...
  • Page 23: Intermittent/Standing Pilot Mode

    IMPORTANT NOTE: When opening the lower door on the face while the insert is burning, pull at the far left or far right vent openings, because the door is hot during operation. WARNING • Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) Electronic Pilot...
  • Page 24: Operation - Model Rdv33/40 Tcc Only

    OPERATION - RDV33/40 TCC Models Only Receiver Remote Control System REMOTE OFF The Remote and Receiver allows you to command the functions of your appliance from the comfort of your chair and is configured to control the On/Off primary burner operation, its flame levels (through six levels) and provides On/Off and Smart thermostatic control of the appliance.
  • Page 25 OPERATION - RDV33/40 TCC Models Only Child Safety Lock-Out Transmission Low Battery Alarm Temperature Indicator Display Thermostat With the system in the “OFF” position, press the Thermostat Key and Room Temperature Off/On/Smart the Mode Key at the same time (see Figure 23). Look at the LCD screen SMART on the Remote to verify that a C or F is visible to the right of the Room Temperature display (see Figure 24).
  • Page 26: Flame Color And Behavior

    OPERATION - RDV33/40 TCC Models Only Burner Flame Appearance Blower Speed Control Soot above Soot at No Soot at Flame Tip Flame Tip Flame Tip This appliance is equipped with a hot air circulating blower. The speed of the blower is controlled by the Remote. The blower speed can be Dark Orange Semi-Transparent Flame...
  • Page 27: Wiring Diagrams

    120 V AC POWER OUTLET ROOM AIR BLOWER AC/DC ADAPTER BURNER PILOT CONTROL NOTE: SWITCH CONDITIONS BOARD GIVEN AT ROOM TEMPERATURE N/C = NORMALLY CLOSED 3-BLK N/O = NORMALLY OPEN = FEMALE DISCONNECT 9 - YLW = MALE DISCONNECT VALVE 8 - GRN 2 - RED = STUD CONNECTION...
  • Page 28 POWER 120 V AC ROOM AIR BLOWER ADAPTOR BOX FAN CONTROL MODULE 14 - RED 4 - PUR 3 - GRAY BURNER NOTE: SWITCH CONDITIONS PILOT CONTROL GIVEN AT ROOM TEMPERATURE BOARD N/C = NORMALLY CLOSED N/O = NORMALLY OPEN = FEMALE DISCONNECT 4-GRN = MALE DISCONNECT...
  • Page 29: Maintenance And Servicing

    o Check that the area around the insert is kept clear and is free of MAINTENANCE AND SERVICING combustible materials, gasoline and other flammable vapors and liquids. WARNING 2. The viewing glass should be cleaned periodically (see Glass Main- tenance). Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 30: Door Removal

    Glass Door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame. •...
  • Page 31: Fuel Conversion

    Repair: If the glass is broken in the glass door, the entire door (metal frame, gasket and glass) should be replaced as a unit. This replacement See Detail B glass door is available from your IHP dealer. Do not use substitute parts or materials.
  • Page 32: Replacing A Damaged Barrier

    Replacing A Damaged Barrier • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier Part No. J7510 (Contemporary Facade) or J7511 (Cast Pillar Facade). Follow installation instruc- tions.
  • Page 33: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 34: Replacement Parts

    REPLACEMENT PARTS - RDV33/40 IPI, RDV33/40 TCC Item # Cat. No. Description H5929 Orifice, Main Burner #49 LP 40,000 BTU H5963 Orifice, Main Burner 1/8" NG 40,000 BTU Item # Cat. No. Description H8481 Pilot Shield H5839 Log Set Support Panel H8491 Pilot Assembly Convertible, NG or LP H8502...
  • Page 35: Replacement Parts

    REPLACEMENT PARTS - RDV33/40 IPI, RDV33/40 TCC Facade Cast Pillar Facade Door NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 36: Accessories

    ACCESSORIES - RDV33/40 IPI, RDV33/40 TCC RDV33 RDV33 Gas Conversion Product Reference Information Kits Cat. No. Description Ship. Ship. Weight Volume H8450 Ravenna IPI 144 lb. 16.9 cu. ft. H8451 Ravenna TCC 144 lb. 16.9 cu. ft. Cat. No. Model Description H8456 RDV-CK-HILO-LP to NG...
  • Page 37 Surround Trim Kits Cat. No. Model Description H5143 GFT2941-B Trim/Black 29" x 41" Contemporary Facade Kits With Barrier H5145 GFT2948-B Trim/Black 29" x 48" H5144 GFT3341-B Trim/Black 33" x 41" H5146 GFT3348-B Trim/Black 33" x 48" 75036 GFT2941-G Trim/Gold 29" x 41" F2322 RDV-CONTF-BLK Contemporary Facade - Black...
  • Page 38 Pillar Cast Face Kits 45-1/2” (1156mm) Note: 3 boxes to complete face 37-5/8" W x 23-3/4" H 7-1/8” (181mm) F2324 PILCST-GLASS-BARRIER Cast Door (Box 1 of 3) 75092 PILCST-PILRS2 Back, Pillars, Top (Box 2 of 3) 44-1/2” (1130mm) 75094 PILCST-GRL-TRD3 Grill/bars Traditional (Box 3 of 3) 30”...
  • Page 39: Insert Labels

    SAFETY / LISTING LABEL - Ravenna IPI SERIAL MODEL Ravenna™ IPI RDV IPI MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS Report No. 14-192 1502 14TH ST NW AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
  • Page 40: Minimum Clearances

    SAFETY / LISTING LABEL - Ravenna TCC SERIAL MODEL Ravenna™ TCC RDV TCC MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS Report No. 14-192 1502 14TH ST NW AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
  • Page 41 LIGHTING LABEL FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. A.
  • Page 42 NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 43: Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IRONSTRIKE.US.COM.
  • Page 44: Product Reference Information

    Normally, all parts should be ordered through your IHP distributor or 1508 Elm Hill Pike, Suite 108 dealer. Parts will be shipped at prevailing prices at time of order. Nashville, TN 37210 visit us at IronStrike.us.com Model Number _____________________________________________________ Serial Number _____________________________________________________ Date Installed ______________________________________________________...

This manual is also suitable for:

Ravenna rdv40 ipiRavenna rdv33 tccRavenna rdv40 tcc

Table of Contents