Set Object Removal Detection - HIKVISION IDS-2CD7546G0-IZHSY 8-32 MM User Manual

Table of Contents

Advertisement

Network Camera User Manual
5. Optional: You can set the parameters of multiple areas by repeating the above steps.
6. For the arming schedule settings, refer to
Linkage Method Settings
to
7. Click Save.

6.2.11 Set Object Removal Detection

Detects if objects are removed from the pre-defined detection region such as exhibits on display. If it
occurs, the device can take linkage actions and the staff can take measures to reduce property loss.
Steps
1. Go to Configuration → Event → Smart Event → Object Removal Detection.
2. Check Enable.
3. Select a Region. For the region settings, see
4. Set the rule.
Sensitivity: Range [1–100]. The percentage of the body part of an acceptable target that leaves the
pre-defined region. Sensitivity = 100 – S1/ST*100. S1 stands for the target body part that leaves
the pre-defined region. ST stands for the complete target body.
EXAMPLE:
If you set the value as 60, a target will be counted as a removed object only when 40
percent of the body part leaves the region.
Threshold: Range [5–100s], the threshold for the time of the objects removed from the region. If
you set the value as 10, alarm is triggered after the object disappears from the region for 10s.
UM Network Camera User Manual 071421NA
Figure 8, Set Rule
Set Arming Schedule
.
Draw Area
. For the linkage method settings, refer
.
54