Bulk/Absorption Voltage
(Sealed/GEL, AGM/LFP,
Flooded)
Float Voltage
Equalization Voltage
Temperature Compensation
USB charger
Low Voltage Disconnect
(USB)
Operating Temperature
Display Operating
Temperature
Humidity
Protection

2.0 IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS FOR
MODEL GP-PWM-10-FM THAT SHOULD BE FOLLOWED
DURING INSTALLATION AND MAINTENANCE OF THE GP-
14.1/14.4/14.4 VDC
(25°C / 77°F), 30min / Day
or 2hr if battery voltage < 12.3 VDC
13.7V (25°C / 77°F), 14.0V (LFP)
14.9V (25°C / 77°F),
or if battery voltage < 12.1 VDC
- 24mV/ºC / -13mV/ºF
Reconnects once battery reaches
- 40 to 85°C / - 40 to 185°F
- 10 to 55°C / 14 to 131°F
Battery Reverse Polarity, Solar Array
Reverse Polarity, Over Temperature,
PV Short Circuit, Over Current
PWM-10-FM.
Disconnect all
power sources
2h / 28 Days
5V, 1500mA
11.0 VDC
12.8 VDC
99% N.C.
Electricity can be very dangerous. Installation
should be performed only by a licensed
electrician or qualified personnel.
GP-PWM-10-FM
Compensated
• RoHS Compliant,
Environmentally Safe
• Accepts up to 160
Watts of Solar at 12
Volts