Operating Environment; Compatible Computers; Before Starting Operations - Epson EMP-6100 Operation Manual

Epson emp-6100: user guide
Hide thumbs Also See for EMP-6100:
Table of Contents

Advertisement

Operating Environment

You can display status information on a computer screen for multiple
projectors that are connected to a network and also carry out batch operations
on all projectors such as turning the power on and off and changing the image
source. A maximum of 64 projectors can be monitored and controlled by batch
operations.
Projector A
Projector B
Projector C
System configuration example
TIP
If the projector's "Network Monitoring" or "Standby Mode"
configuration menu is set to "ON" or "Network ON", the projector
can still be monitored when it is in standby mode (when the
indicator is lit orange).
Turn on
projector B
EMP Monitor
(Power)

Compatible computers

* Macintosh computers cannot be used.
OS*
98SE/Me/NT4.0/2000 Professional/XP Home Edition/XP
Professional
CPU
Pentium MMX 166 MHz or higher (Pentium II 233 MHz
or higher recommended)
Memory
64 MB or more (128 MB or more recommended)
capacity
Free hard disk
6 MB or more
space
Display
XGA (1024×768) or higher resolution, 16 bit or higher
display colour

Before starting operations

Check the following points before starting up EMP Monitor.
• EMP Monitor must be installed in the computer to be used for monitoring
and control.
• The computer and the projectors must be connected to the network.
• If using Windows 2000, NT4.0 or XP, the computer must be started up in
Administrator mode.
(When using EMP-81/61)
• To use EMP Monitor, an adapter and cable for conversion are required.
sUser's Guide "Standby mode"
• You need to make a setting for the adapter before connecting it to the
projector. sThe adapter's documentation
Refer to the "Appendices" for details about the adapter setting.
3
sp.12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emp-8100Emp monitor

Table of Contents