Connect Power

The Electrical Control Panel comes already attached
and wired to the Ram, however before the supply unit
becomes functional you must connect the Electrical
Control Panel to a power source.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
NOTE: Required voltage and amperage is noted on the
Control Panel label. Before running power to the unit,
make sure the plant electrical service meets the
machine's electrical requirements. Branch circuit
protection shall be provided by the end user.
Use copper conductors rated 600 volts minimum and
167°F (75°C) minimum only. Torque to 55 in-lb (6.2
N•m).
Table 2 Electrical Requirements
Electric
al Panel
Hz
Phase
Voltage
230 V
50/60
3
400 V/N 50/60
3
400 V
50/60
3
480 V
50/60
3
600 V
50/60
3
EF Standard Finned Bottom
EM Mega-Flo
ES Smooth Bottom
1. Locate the opening in the Control Panel's top
housing for the conduit that will enclose the wire
from the facility's power source. The hole will
accept a cord diameter range of 0.7–1.2 in (17–30
mm).
2. Route the wire from the power source into the
Control Panel housing, and then connect the power
source wires to the appropriate terminals on the
DISCONNECT switch.
334129S
Full
Platen
Load
AWG
Amps
EF, ES
50
8 AWG
EF, ES
30
8 AWG
EF, ES
30
8 AWG
EF, ES
30
8 AWG
EF, ES
25
8 AWG
F
. 14
IG
To reduce the risk of fire, explosion, or electric shock,
the resistance between the supply unit components
and true earth ground must be less than 0.25 ohms.
3. Connect the ground wire to the ground lug. Have a
qualified electrician check the resistance between
each Therm-O-Flow system ground and the true
earth ground. The resistance must be less than
0.25 ohms. If the resistance is greater than 0.25
ohms, a different ground site may be required. Do
not operate the system until the problem is
corrected.
NOTE: Use a meter that is capable of measuring
resistance at this level.