Graco Therm-O-Flow 20 Instructions - Parts Manual page 45

Hide thumbs Also See for Therm-O-Flow 20:
Table of Contents

Advertisement

Code
Description
V8M#
No Line Voltage
MZLP _
V4M#
AWB High Line
Voltage
WJ1
Pump _ Solenoid is
disconnected
WJ2
Pump _ Solenoid
High Current
WSUX
Configuration Error
USB
334129S
Type
Cause
Alarm
Incoming line
voltage is less
than 100 VAC.
Alarm
Incoming
voltage is too
high
Alarm
Pump is not
turning on
when it should
Alarm
Solenoid is
drawing too
much current
Advisory
USB
configuration
is not loaded
Solution
Verify Transformer has the correct tap
selected.
Verify CB-1 or FU-4, FU-5, and FU-6 are not
tripped/blown.
Verify RCD-1 is not tripped.
Measure incoming power with system
unplugged. If line voltage is less than 100 VAC,
contact qualified electrician to correct the low
voltage.
Verify the MZLP is plugged in at J2 and the
AWB is plugged in at J5 or J6.
Check incoming voltage is correct for
configuration.
Verify the transformer has the correct tap (400,
480, 600) selected.
Verify harness is plugged into J13 of the
daughter board. Verify it is secured to the
solenoid.
Replace Solenoid.
Inspect for short in harness. Inspect for a
shorted solenoid cable/short to the ground.
Replace solenoid.
Install software.
Troubleshooting
45