Electric Storage Water Heaters
Standard Models:
80T118, 80T124, 80T136, 125T118, 125T136,
125X118, 125X136, N135T118, N135T130,
160T124, 160T136, 180TD124, 180TD130,
180ST124, 180ST130, 250T118, 250T136,
N250T124, N250T130, N300T124, N300T130,
315T136, 315T236, 315T248, 400T136, 400T236
An 'H' at the end of the model number indicates that the
water heater is fitted with a hard-water anode.
Installation Details
Owner's Information
Warranty
For advice, repairs and service, call:
1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Specifications and materials may change without notice.
Effective for the above model numbers of Proflo electric storage water heaters manufactured and
sold after 1st September 2021.
H0421
0421
Rev. R

Advertisement

loading
Need help?

Need help?

Do you have a question about the proflo N135T118 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dux proflo N135T118

  • Page 1 Owner’s Manual Electric Storage Water Heaters Standard Models: 80T118, 80T124, 80T136, 125T118, 125T136, 125X118, 125X136, N135T118, N135T130, 160T124, 160T136, 180TD124, 180TD130, 180ST124, 180ST130, 250T118, 250T136, N250T124, N250T130, N300T124, N300T130, 315T136, 315T236, 315T248, 400T136, 400T236 An ‘H’ at the end of the model number indicates that the water heater is fitted with a hard-water anode.
  • Page 2 Owner’s Manual – Proflo Electric Storage Water Heaters Important Safety Information WARNING – THIS APPLIANCE To dissipate this gas safely it is MAY DELIVER WATER AT HIGH recommended that a hot tap be turned on TEMPERATURE. REFER TO THE for several minutes at a sink, basin or bath, PLUMBING CODE OF AUSTRALIA but not a dishwasher, clothes washer or (PCA), LOCAL REQUIREMENTS...
  • Page 3 Turn off the water heater and contact Dux The water heater must not be operated After Sales and Service. unless this device is fitted and in working OVER-TEMPERATURE ENERGY order.
  • Page 4 The pipework must Method for Clause G12 of the NZBC. Other not be used to support the water heater. methods of compliance are available. Dux recommends that installations conform with Where the water heater is subjected to wet AS/NZS 3500.4.
  • Page 5: Table Of Contents

    Owner’s Manual – Proflo Electric Storage Water Heaters Contents Important Safety Information Installation Requirements Plumbing Connections Specifications Filling and Draining Electrical Connection System Maintenance Considering a Service Call? Warranty © Dux Manufacturing Limited 2021. All rights reserved. H0421 0421 Rev. R...
  • Page 6: Plumbing Connections

    Owner’s Manual – Proflo Electric Storage Water Heaters Plumbing Connections Relief Valve: AS/NZS 3500.4 for guidance on these types The Pressure & Temperature Relief (PTR) Valve of installations. is supplied either inside the electrical cover of the water heater or in a bag attached to the Hot Water Connection: water heater.
  • Page 7 Incoloy heating element. Please and the water heater. consult Dux After Sales and Service for advice if required. Cold Water Connection: The water heater is intended to be permanently connected to the water supply main, and not connected by a hose-set.
  • Page 8: Specifications

    Owner’s Manual – Proflo Electric Storage Water Heaters Specifications 80L - 400L (Dual Handed Models) 125L Narrow Diameter (Dual Handed Models) Nominal Dimensions (mm) 315T1/ 400T1/ Model 80T1 125T1 125X1 160T1 250T1 315T2 400T2 Total Height (A) 1090 1300 1315 1445 1765 1705...
  • Page 9 Owner’s Manual – Proflo Electric Storage Water Heaters Specifications N135T1 & 180TD1 180ST, N250T1 & N300T1 25° OVERALL 45° Nominal Dimensions (mm) Nominal Dimensions (mm) Model N135T1 180TD1 Model 180ST N250T1 N300T1 Total Height (A) 1298 1776 Total Height (A) 1190 1566 1804...
  • Page 10: Filling And Draining

    Owner’s Manual – Proflo Electric Storage Water Heaters Filling and Draining Filling the Water Heater: Draining the Water Heater: The water heater must be filled with water Turn off the electricity supply to the before turning on the electrical supply. water heater.
  • Page 11: Electrical Connection

    Owner’s Manual – Proflo Electric Storage Water Heaters Electrical Connection General: Connect the active and neutral wires to the This water heater is designed for single phase terminal block and the earth wire to the earth tab 230 - 240V a.c. supply only. The electrical (located on the right hand side).
  • Page 12: System Maintenance

    This service should only be carried out by safely and efficiently. a licensed tradesperson. We recommend your local Dux Service Agent. Your water heater warranty is not conditional on completing the regular In locations where the water has Total servicing recommended in this manual.
  • Page 13: Considering A Service Call

    • Is the water heater the correct size for the requirements? Sizing details are contact Dux After Sales and Service. available from your Dux supplier. • Is there a leaking hot water pipe or dripping hot water tap? A small leak can waste a large quantity of hot water.
  • Page 14: Warranty

    (as more than 100km from a Dux office or Dux specified in the table above). Conditions apply. agent, the Owner will be responsible under the...
  • Page 15 To the extent permitted by law the liability of covered by the warranty or guarantee, you Dux shall be limited to the cost of the repair or will be responsible for the costs incurred by replacement of the water heater.
  • Page 16 Please take a moment to fill out your details for warranty Electric Storage Water Heaters registration at: www.dux.com.au/warranty For advice, repairs and service, call: or use your smartphone to scan this code: 1300 365 115 (Australia) 0800 729 389 (New Zealand)