Continuous Drainage

If a drain is available, the unit can continuously drain excess water by attaching a commercially available hose
(internal diameter 15 mm).
The unit can be operated for extensive periods without the need to empty the water tank.
Commercially available hose
Items to
(I.D. 15 mm)
prepare
Long enough to reach the drain
Nippers or the like
How to set up the drainage hose
Correctly
Incorrectly
installed
installed
<Preparation> Turn the POWER switch "OFF",
and remove the power plug.
Remove the
1
water tank.
Grasp handle and
slide out.
Open the continuous
2
drainage outlet.
Use nippers or the like to cut the fi xing ribs (three
places) of the continuous drainage outlet on the
back of the unit, and remove it from the outlet (while
taking care not to injure yourself on a cut surface).
Use a fi nger to press the
3
stopper of the drainage outlet.
When you will perform continuous drainage, leave at least 20 cm of space from the surface with the outlet for the hose.
Confi rm that the hose does not show signs of deterioration such as bending cracks and clogging.
Inspect the hose every 2 weeks. Insects or dirt blocking the hose may cause leakage resulting in malfunctions.
e̲mj̲ez6cx̲s1.indb   17
e̲mj̲ez6cx̲s1.indb   17
hose immersed in water
hose raised to a
level higher than the
drainage outlet
The water will not
drain.
Position of
drainage outlet
115 mm
45 mm
Drainage outlet
Stopper
Press here
CAUTION
Do not drain water continuously if there
is a possibility that temperatures around
the hose could drop below freezing point.
Water inside the hose may freeze and water may leak
from the unit and damage surrounding objects.
When draining water continuously or left
unattended for long periods, inspect the
unit once a fortnight.
Foreign objects, etc. could clog the hose resulting in
overheating and/or leakage.
Insert the hose through the
4
continuous drainage outlet
from the back of the unit.
1 Feed the commercially available hose
(internal diameter of 15 mm) into the
continuous drainage outlet while keeping the
stopper pressed.
2 Firmly push the hose
through the drainage
outlet of the unit.
3 Check for water
leakage.
Attach the tank to the unit,
5
and place the end of the hose
in the drain location.
If the tank is not reattached, the "FULL lamp"
remains on and operation is not possible.
Drain
Hose
17