SelecType Init
Restores the control panel menu settings to their default values.
Yellow Regist, Magenta Regist, and Cyan Regist settings are not
reset.
Parallel Menu
These settings control communication between the printer and
the computer when using the parallel interface.
Item
Parallel I/F
Speed
Bi-D
Buffer Size
Parallel I/F
Allows you to activate or deactivate the parallel interface.
Speed
Specifies the pulse width of the ACKNLG signal when receiving
data in the Compatibility mode or Nibble mode. When Fast is
selected, the pulse width is about 1 s. When Normal is selected,
the pulse width is about 10 s.
Bi-D
Allows you to specify the bidirectional communication mode.
When you select Off, bidirectional communication is disabled.
Settings (default in bold)
On, Off
Fast, Normal
Nibble, ECP, Off
Normal, Maximum, Minimum