Setting a Reference for Far End Source Mode

1.
Turn on the test tool and the optional source. Set the remote end
configuration to Far End Source Mode. Let the DSP-FTA410 units warm
up for five minutes. Let the optional source warm up as required.
2.
Choose two known-good patch cords with the appropriate connector types.
Clean all fiber connectors.
3.
Make the connections shown in Figure 7.
Turn the rotary switch to SPECIAL FUNCTIONS. Select Set Fiber
4.
Reference; then press E.
OUTPUT
INPUT
DSP-FTA410
FIBER TEST ADAPTER
DSP-4000
CABLE ANALYZER
1
2
3
4
EXIT
FAULT
TALK
INFO
SAVE
TEST
ENTER
MONITOR
SINGLE
SETUP
TEST
AUTO
PRINT
TEST
SPECIAL
OFF
FUNCTIONS
Figure 7. Setting a Reference for Far End Source Mode
Optical patch cords
(SC at test tool end)
Test tool
with fiber test
adapter
Setting Up for Fiber Tests
Adapter
Optical source
(such as
Fluke LS-1310/1550
or FOS-850/1300)
CW
MOD
1310 OFF 1550
CAUTION
SOURCE ACTIVE
LOW BATTERY
LS-1310/1550
LASER SOURCE
tt05f.eps