Single Tests For Loopback Mode; Single Test For Far End Source Mode - Fluke DSP-FTA410 User Manual

Fiber test adapter
Hide thumbs Also See for DSP-FTA410:
Table of Contents

Advertisement

Single Tests for Loopback Mode

Use these tests to troubleshoot fiber links, test patch cords, and check spools of
fiber before installation.
Total Loss: Measures the optical power loss between the output and
input ports of the DSP-FTA410 unit. If two fibers are connected end-to-
end with a loopback cable, the total loss of both fibers is displayed.
Total Length: Measures the total length of the fiber between the
output and input ports of the DSP-FTA410 unit. If two fibers are
connected end-to-end with a loopback cable, the total length of all fibers is
displayed.
Propagation Delay: Measures the total propagation delay of the
of the fiber between the output and input ports of the DSP-FTA410 unit.
Power: Measures the optical power received at the input port on the
main unit. Power is measured at 850 nm and 1300 nm.
Send (850 nm or 1300 nm): Continuously transmits a 850 nm or
1300 nm optical signal at the output port.

Single Test for Far End Source Mode

The Receive test, which requires a separate multimode or singlemode
source at the far end, continuously measures optical power at the main unit.
With a multimode source, you can measure power at 850 nm or 1300 nm. With
a singlemode source, you can measure power at 1310 nm or 1550 nm.