Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation.
Electrical power MUST remain off until installation is complete.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 lb.
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Read this entire installation manual to ensure proper installation. When finished with the installation, file
this manual with the owner or maintenance department. Compliance and conformity to local codes and
ordinances is the responsibility of the installer. Product warranties may be found under "Products" on our
website at bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the
finished floor.
215-1816 Rev. H: ECN 19-08-037F
© 2020 Bradley
Page 1 of 40
3/2/2020
Installation
ELX-3
Express
Système lave-mains Express
Sistema de lavabo Express
WARNING
NOTICE
IMPORTANT
Lavatory System – ELX-Series
®
P.O. Box 309
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
bradleycorp.com
– Série ELX
®
– Serie ELX
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Express ELX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bradley Express ELX Series

  • Page 1 For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the finished floor. P.O. Box 309 215-1816 Rev. H: ECN 19-08-037F Menomonee Falls, WI 53052 USA © 2020 Bradley 800 BRADLEY (800 272 3539) +1 262 251 6000 Page 1 of 40 3/2/2020 bradleycorp.com...
  • Page 2: Table Of Contents

    Conjunto de desagüe ..................................37 Montaje de la palangana ................................38 Filtro y sifón en P ..................................38 Adjuste la temperatura .................................. 39 Cubierta del sifón ..................................39 Limpieza y mantenimiento ................................40 Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 3: Components

    (½" NPTM Outlet) Plastic Hose (S45-2701) Hose Plastic Hose Supply Fittings Plastic (Standard) Hose (S45-2513) Plastic (S45-3005) Hose for Verge Faucets Stainless Steel Hose Prepack S53-3100, S53-3300, Hose (S45-2730) S53-3500, & S53-3700 Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 4: Supplies Required

    Top View (shown with shared soap) 30" 30" (762) (762) 15" 15" (381) (381) 6" 6" 6" (152) (152) (152) 5" 21⁵⁄₈" (127) (549) A = personal soap locations Front View 66³⁄₄" (1695) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 5 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 26" *Subtract 7½" Junior For use by younger children where ADA guidelines are not a concern. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 6: Rough-Ins

    Provide structural backing compliant with local building codes. Rim Height Vertical Height Adjustments Fixture Style 33½" No Adjustment Standard, ADA & TAS 30½" Subtract 3" Juvenile, ADA & TAS 26" Subtract 7½" Junior Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 7 Use alternate location for electrical outlet and faucet control box for multi-feed systems 110V GFI protected electrical outlet (AC faucet and soap only) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 8 Use alternate location for electrical outlet and faucet control box for multi-feed systems 110V GFI protected electrical outlet (AC faucet and soap only) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 9 1½" NPT Drain, Stub-out 2" from wall, combined waste option (waste arms to be cut in field) ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 110V GFI protected electrical outlet (AC faucet and soap only) #10 Anchors for Faucet Control Box Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 10: Bracket Mounting

    Step B and marked at 28" both to the left and right of the center bracket. Secure the brackets to the wall anchors using fasteners per the structural rough-in requirement (supplied by installer). (3x) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 11: Overflow Plug Assembly

    Screw Assemble the remaining components as shown and thread the four screws through the drain adapter and into the basin inserts. Ensure the screws compress the drain adapter evenly onto the basin. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 12: Bowl Mounting

    Ensure bowl is level. Strainer and P-Trap Ensure not to overtighten the strainer screw. Strainer Thread the strainer screw through the strainer and into the stand off on the drain adapter. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 13: Adjust Temperature

    Finishing #10-24 Flat Head Screw Washer (160-520) (142-002CA) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 14: Cleaning And Maintenance

    For complete instructions on this additional maintenance, visit bradleycorp.com. Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days.
  • Page 15 Pour les poses de hauteur standard, ne pas dépasser la distance conseillée de 851mm (33,5") entre le rebord de l’appareil sanitaire et le sol fini. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 16: Composants

    (Sortie ½" NPTM) (S45-2701) Tuyau en plastique Tuyau en Raccords d’alimentation plastique (Standard) (S45-2513) Tuyau en plastique (S45-3005) Tuyau for Verge Faucets Trousse tuyaux en acier (S45-2730) S53-3100, S53-3300, inoxydable S53-3500, & S53-3700 Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 17: Fournitures Requises

    Vue de dessus (représenté avec distributeurs de savon communs) 30" 30" (762) (762) 15" 15" (381) (381) 6" 6" 6" (152) (152) (152) 5" 21⁵⁄₈" (127) (549) A = emplacement des distributeurs de savon personnels Vue de face 66³⁄₄" (1695) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 18 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 660mm (26") *Retrancher 191mm (7-1/2") Junior For use by younger children where ADA guidelines are not a concern. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 19 Hauteur du rebord Ajustements de la hauteur Type d’appareil 851mm (33-1/2") Pas d’ajustement Standard, ADA & TAS 775mm (30-1/2") Retrancher 76mm (3") Enfants, ADA & TAS 660mm (26") Retrancher 191mm (7-1/2") Junior Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 20 Arrivées d’eau chaude/froide de ½" nominal (comp. ⁵⁄₈" dia. ext.), tubulure à 51mm (2") du mur Prise électrique 110 V à disjoncteur à protection DDFT (GFI) (pour robinets et distributeurs de savon électriques uniquement) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 21 Arrivées d’eau chaude/froide de ½" nominal (comp. ⁵⁄₈" dia. ext.), tubulure à 51mm (2") du mur Prise électrique 110 V à disjoncteur à protection DDFT (GFI) (pour robinets et distributeurs de savon électriques uniquement) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 22 Arrivées d’eau chaude/froide de ½" nominal (comp. ⁵⁄₈" dia. ext.), tubulure à 51mm (2") du mur Prise électrique 110 V à disjoncteur à protection DDFT (GFI) (pour robinets et distributeurs de savon électriques uniquement) #10 Anchors for Faucet Control Box Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 23: Raccordements

    Step B and marked at 28" both to the left and right of the center bracket. Secure the brackets to the wall anchors using fasteners per the structural rough-in requirement (supplied by installer). (3x) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 24: Assemblage Du Bouchon De Trop-Plein

    Assembler les composants restants comme indiqué, puis enfoncer les quatre vis à travers l’adaptateur d’écoulement et serrer les vis dans les inserts de la vasque. Vérifier que les vis compriment l’adaptateur d’écoulement uniformément sur la vasque. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 25: Fixation De La Vasque

    Tamis et siphon en P Veiller à ne pas trop serrer la vis du tamis. Tamis Enfoncer la vis du tamis à travers le tamis, puis serrer la vis dans l’entretoise de l’adaptateur d’écoulement. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 26: Fair Couler L'eau Pour Régler La Température

    à l’aide des vis et des rondelles de finition fournies, en commençant du côté gauche ou du côté droit. Vis à tête plate Rondelle de n° 10-24 (160-520) finition (142-002CA) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 27: Nettoyage Et Entretien

    Trousses de réparation : Des nécessaires de réparation Terreon sont disponibles. S’adresser au représentant ou distributeur Bradley pour connaître les numéros de référence et les prix. Les trousses de réparation sont préparées sur commande et ont une durée de conservation de 30 jours.
  • Page 28 Saque las piezas del embalaje y asegúrese de haberlas sacado todas antes de desecharlo. Si falta alguna pieza, no comience la instalación hasta obtenerla. Para montaje en altura estándar, no exceda la distancia recomendada de 851mm (33,5") desde el borde del accesorio hasta el piso terminado. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 29: Componentes

    Manguera de plástico Manguera Conexiones de suministro de plástico (Standard) (S45-2513) Manguera de plástico Conjunto (S45-3005) Manguera de preempaquetado for Verge Faucets acero inoxidable de manguera S53-3100, S53-3300, (S45-2730) S53-3500, & S53-3700 Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 30: Materiales Necesarios

    Vista superior (mostrada con jabón compartido) 30" 30" (762) (762) 15" 15" (381) (381) 6" 6" 6" (152) (152) (152) 5" 21⁵⁄₈" (127) (549) A = ubicación del jabón personal Vista delantera 66³⁄₄" (1695) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 31 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 660mm (26") *Reste 191mm (7-1/2") Para niños For use by younger children where ADA guidelines are not a concern. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 32: Colocación De Las Tuberías Empotradas

    Ajustes de altura vertical Estilo del accesorio 851mm (33-1/2") Sin ajuste Estándar, ADA y TAS 775mm (30-1/2") Reste 76mm (3") Para menores, ADA y TAS 660mm (26") Reste 191mm (7-1/2") Para niños Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 33 51mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 34 51mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) #10 Anchors for Faucet Control Box Installation #10 Anchors for Soap Tank Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 35 Suministros de agua fría y caliente de ½" nominal (diám. ext. comp. de ⁵⁄₈"), H y C salen 51mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) #10 Anchors for Faucet Control Box Installation Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 36: Montaje De La Estructura

    Step B and marked at 28" both to the left and right of the center bracket. Secure the brackets to the wall anchors using fasteners per the structural rough-in requirement (supplied by installer). (3x) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 37: Conjunto De Tapón Contra Desbordes

    Asegúrese de que los tornillos compriman el adaptador de desagüe de manera uniforme en el lavamanos. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 38: Montaje De La Palangana

    Filtro y sifón en P Asegúrese de no apretar en exceso el tornillo del filtro. Filtro Enrosque el tornillo del filtro a través del filtro y en el separador del adaptador de desagüe. Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 39: Adjuste La Temperatura

    Tornillo de cabeza plana Arandela de n.º 10-24 (160-520) acabado (142-002CA) Bradley • 215-1816 Rev. H: ECN 19-08-037F 3/2/2020...
  • Page 40: Limpieza Y Mantenimiento

    Kits de reparación: Existen kits de reparación de Terreon. Comuníquese con su representante o distribuidor de Bradley para conocer los números de pieza y los precios. Los kits de reparación se hacen a pedido y su caducidad es de 30 días.

This manual is also suitable for:

Express elx-3S93-738S93-732S93-739

Table of Contents