 Load status indicator:
When the load current is 1.25times of rated current for 60 seconds, or the load current is
1.5 times of rated current for 5 seconds (overload); or load current is more than 3.5
times of rated current(Short Circuit) ,the load status indictor will be red and flashing.
Please refer to section 5 for trouble shooting.
Load status indicator
Table 4-3
Color
indictor
Load status
Red
flashing
Overload or short circuit
 Overheating protection indicator:
When heat sink of the controller exceeds 85 ℃, the controller will automatically cut input
and output circuit, Sealed, Gel, Flooded indicator will be red and flashing simultaneously.
Please refer to section 5 for trouble shooting.
Overheating protection indicator
Table 4-4
Color
indictor
System status
Sealed、Gel、Flooded
Controller overheating
Red
flashing simultaneously