Load status indictor red and
flashing
Sealed、Gel、Flooded
indicator flashing
simultaneously
Notes: No LED indicator.
Measure battery voltage with multimeter.
Min.6V can start up the controller.
Notes: No charging status LED indicator with normal connection.
Measure the input voltage of solar module, the input voltage must
be higher than battery voltage!
Over load or short
circuit
Too high
temperature of
controller
18
Overload: reduce the load
and press the button once,
the controller will resume
to work after 3s;
Short circuit: when the first
short-circuit occurs, the
controller will
automatically resume to
work after 10s; when a
second short-circuit occurs,
press the button, the
controller will resume to
work after 3s.
When heat sink of the
controller exceeds 85 ℃ , the
controller will
automatically cut input and
output circuit. When the
temperature below 75℃ , the
controller will resume to
work