Maintenance - WESTECH SeaStar SS1024 Instruction Manual

Moisture proof solar controller
Table of Contents

Advertisement

5.3 Maintenance

The following inspections and maintenance tasks are recommended at least two times per
year for best controller performance.
 Check that the controller is securely mounted in a clean and dry environment.
 Check that the air flow and ventilation around the controller is not blocked. Clear all
dirt or fragments on the heat sink.
 Check all the naked wires to make sure insulation is not damaged for serious
solarization, frictional wear, dryness, insects or rats etc. Maintain or replace the wires if
necessary.
 Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
 Check and confirm that LED digital tube is consistent with required. Pay attention to
any troubleshooting or error indication .Take necessary corrective action.
 Confirm that all the system components are ground connected tightly and correctly.
 Confirm that all the terminals have no corrosion, insulation damaged, high temperature
or burnt/discolored sign, tighten terminal screws to the suggested torque.
 Inspect for dirt, insects and corrosion, and clear up.
 Check and confirm that lightning arrester is in good condition. Replace a new one in
time to avoid damaging of the controller and even other equipments.
Notes: Dangerous with electric shock!
Make sure that all power source of controller is cut off when
operate above processes, and then make inspection or other
operations!
19