3-1. Error Message
Error messages are described in the order of error codes on the next pages and later.
If multiple errors occur, the priority level of the error code display are as follows:
92, 93, 96, 91, 97, 98, 02, 03, 04, 05, 07, 06, 01, 09, 08, 0A, 10, 11, 12, 13, 20, 21,
22 , and 23
The "protection mode" described in this text means the servo control system auto-
matically stops the tape transport and drum motor rotation, and maintains this state.
The unit cannot be automatically recovered to the normal state when the unit once
enters the protection mode. When the protection mode is entered with the cassette
tape inserted, take out the cassette tape manually with reference to section 2-12 (on
page 2-22). Never turn the power on again without taking out the cassette tape.
This may damage the tape.
Error List
Code
Message
on time data display area
01
REEL TROUBLE
02
REEL TROUBLE
03
REEL TROUBLE
04
REEL TROUBLE
05
REEL TROUBLE
06
TAPE TENSION
07
CAPSTAN TROUBLE
08
DRUM TROUBLE
09
TH/UNTH MOTOR
0A
THREADING TROUBLE
10
HUMID
11
TAPE T/E SENSOR
12
TAPE TOP SENSOR
13
TAPE END SENSOR
14
FAN MOTOR
20
CASS COMP MOTOR
21
REEL SFT MOTOR
22
REEL POS SENSOR
23
THREAD RING SENS
90
NO COMMUNICATION
91
SYSTEM REFERENCE
92
INTERNAL I/F
93
CPU INITIALIZE
96
SY NVRAM
97
SV NVRAM
98
RF NVRAM
3-2
Page
Description
3-3
Tape slacking is detected in the threading or unthreading operation.
3-4
Tape slacking or tape breaking is detected in the SEARCH, FF, or REW mode.
3-5
Tape slacking, tape breaking, or supply or take-up reel locking is detected in the REC or
PLAY mode.
3-6
An malfunctional tape transport speed is detected in the FF or REW mode.
3-6
The malfunctional operation of the supply or take-up reel is detected during cassette
insertion.
3-7
Excessive tape tension is detected in the REC or PLAY mode.
3-7
Malfunction of capstan motor is detected.
3-8
Malfunction of drum motor is detected.
3-8
Malfunction of threading or unthreading operation is detected.
3-9
It is detected that the tape top processing is not completed in the threading mode.
3-9
Dew condensation is detected.
3-10
The tape top and tape end are detected simultaneously.
3-10
Malfunction of tape top sensor is detected.
3-11
Malfunction of tape end sensor is detected.
3-12
Malfunction of cooling fan motor is detected.
3-13
Malfunction of cassette compartment-up or down operation is detected.
3-13
Malfunction of movement of the reel table corresponding to the cassette size is detected.
3-14
The L-cassette and S-cassette positions of the reel table are detected simultaneously.
3-14
The thread end and unthread end states of the threading ring are detected simultaneously.
3-15
Abnormality is detected in the communication with control panel (KY-364 board).
3-15
Abnormality is detected in a system reference signal (VD).
*
Abnormality is detected in the interface between SS-63 board and other boards.
*
Abnormality is detected during the servo system initialization at turn on the power state.
*
The abnormal operation of an NV-RAM (Non-volatile RAM) (on the SS-63 board) in
system control system is detected.
*
The abnormal operation of an NV-RAM (MS-50 board) in servo system is detected.
*
The abnormal operation of an NV-RAM (EQ-56 board) in RF system is detected.
: Be not described.
*