Sony DNW-A100 Maintenance Manual page 33

Digital video hybrid recorder
Hide thumbs Also See for DNW-A100:
Table of Contents

Advertisement

SS-63 board switch
Switch No.
Name
S100
REEL POSITION
S101
1
FLASH MEMORY
2
ANA AUTO-TRACKING
3
ANA DISABLE
4
SV ERR DISABLE
S700
SYSTEM RESET
S1100
1
EXTENDED MENU
2
MAINTE MODE ACCESS OFF (OPEN) : Not enter into maintenance mode from lower control panel OFF (OPEN)
3
—————
|
8
S1101
MAINTE MODE START
S1102
nNever change the settings of the S1102 switch since each switch is set according to the characteristics of the
unit.
But set this switch according to each unit when replacing the board.
1, 2
MODEL ID SWITCH
3
J/UC
4
525/625
S1900
1
—————
|
8
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Description
Press this switch when changing the reel position.
This switch does not operate in the state of installing the cassette compertment
nDo not change the setting of this switch during installation.
Select the operation mode of flash memory
OFF (OPEN) : Normal mode
ON (CLOSE) : Writing mode
Select whether to enable auto tracking operation or not during playing
back the tape recorded based on the Betacam/Betacam SP format.
OFF (OPEN) : Not operate
ON (CLOSE) : Operates
n The Betacam SX tape playback is carried out by non-tracking operation.
Select whether to prohibit analog Betacam tape playback or not.
OFF (OPEN) : Enable
ON (CLOSE) : Disable
n Do not change the setting of this switch during installation.
This switch selects whether to disable the detection of a malfunctional
error in a servo circuit.
OFF (OPEN) : Enable (normal)
ON (CLOSE) : Disable
Press this switch when resetting system control operation.
OFF (OPEN) : Not display extended menu of set up menu
ON (CLOSE) : Displays extended menu of set up menu
ON (CLOSE) : Enters into maintenance mode from lower control panel
Factory use
Press this switch when starting maintenance mode
1
Reserved
: OFF (OPEN)
DNW-A100/A100P : OFF (OPEN)
DNW-A50/A50P
: ON (CLOSE)
DNW-A45/A45P
: ON (CLOSE)
OFF (OPEN) : Japan model
ON (CLOSE) : Except Japan model
OFF (OPEN) : 525/60 model
ON (CLOSE) : 625/50 model
Factory use
1-10. Switch and Shorting Plug Setting on PC Boards
2
OFF (OPEN)
ON (CLOSE)
OFF (OPEN)
ON (CLOSE)
NTSC model : OFF (OPEN)
PAL model : ON (CLOSE)
Factory setting
—————
OFF (OPEN)
ON (CLOSE)
OFF (OPEN)
OFF (OPEN)
—————
OFF (OPEN)
OFF (OPEN)
—————
—————
ON (CLOSE)
OFF (OPEN)
1-21