1-18. Installation of BKNW-104
5. Component Video Input Phase (Betacam) Adjustment
Refer to 1-42 page for operation method of the maintenance mode when adjusting.
(1) Connect as connection 2.
(2) Select "Y INPUT PHASE" of A22: AD VR (LOOP) of maintenance mode.
(3) Magnify the horizonal axis on the screen of the waveform monitor, then display 2T pulse.
(4) Adjust that 1st signal and signal after looping overlap.
ANALOG COMPONENT OUT
Before adjustment
1st signal
t
(5) Set the waveform monitor to BOWTIE mode.
(6) Select "Y/R-Y INPUT DELAY".
(7) Measure the cross point of Y and R-Y (BOWTIE DIP point), then adjust "Y/R-Y INPUT DELAY"
that the deviation between the dip point and the center marker satisfies the specifications.
(8) Select "Y/B-Y INPUT DELAY".
(9) Measure the cross point of Y and B-Y (BOWTIE DIP point), then adjust "Y/B-Y INPUT DELAY"
that the deviation between the dip point and the center marker satisfies the specifications.
Specification : A = 0 ±20 ns Specification : B = 0 ±20 ns
(10)After completing the adjustment, push the MENU button once so as to exit A22: AD VR (LOOP).
(11)Select A2F: NV-RAM CONTROL and save the adjusted data in NV-RAM (execute "SAVE ALL
ADJUST DATA").
(12)Check that "Save Complete" is displayed on the video monitor screen.
(13)Push the MENU button once so as to exit A2F: NV-RAM CONTROL.
1-46
After adjustment
Looped signal
8
A
B
DIP
Y/R-Y
Y/B-Y
t < 20 ns
DNW-A100/A50/A45
DNW-A100P/A50P/A45P