1-3. Operating Conditions

1-4. Power Supply

1-3. Operating Conditions
c
Good air circulaiton is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature : +5dC to +40dC
(When the inner of the unit becomes less than +5dC, the
hard disk portion does not start up because of entering
into heart up mode.
The inner of the unit becomes +5dC or more, the hard
disk portion start up automatically.)
Operating humidity
: 25% to 80%
(Condensation not allowed)
: _20dC to +60dC
Storage temperature
Locations to avoid
:
. Areas where the unit will be exposed to direct sunlight
of any other strong lights.
. Areas near heat sources.
. Dusty areas or areas subject to vibration.
. Areas with strong magnetic field.
. Areas with much electrical noise.
. Areas with much static electricity.
. Areas that is impossible to find a specified room for
installation.
(Refer to "1-5. Installation Space" page 1-3)
Horizonal condition
: Do not slant the front and rear of
the unit more than 30d.
c
Fix the unit securely to avoid slipping if the unit is not
operated at horizonal place.
1-4. Power Supply

1-4-1. Voltage and Power Requirements

w
Be sure to operate the unit within the range of
recommended power voltage.
Recommended power voltage:
Recommended power frequency: 50 Hz or 60 Hz
Power consumption:DNW-A100/A100P; 320 W (320 VA)
DNW-A50/A50P; 300 W (300 VA)
DNW-A45/A45P; 300 W (300 VA)
1-2
AC 100 to 240 V ±10%
Rush current:
Power voltage 100 V IN; 10 A
Power voltage 240 V IN; 20 A
This unit's power line has a switching regulator with the
power factor 98%.
The power consumption just described is includes the
power consumption of a optional board BKDW-505 or
BKDW-506.
n
AC power supply is repuired a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normaly.

1-4-2. Power Cord

w
Use the specified power cord only when connecting.
Never use a injured power cord.
Power cord for the customer in the U.S.A. and Canada.
1Power cord set (approx. 2.4 m)
2Plug holder (Black)
1
Power cord for the customer in the U.K..
1Power cord set (approx. 2.5 m)
2Plug holder (Gray)
Safety earth (Green/Yellow)
1
Live (Brown)
Neutral (Blue)
If the unit destined for Europe is used in the area except
the U.K., please consult with local Sony's sale/service
office.
1-551-812-11
2-990-242-01
AC inlet
2
(DNW)
1-590-910-11
3-170-078-01
AC inlet
(DNW)
2
DNW-A100/A50/A45
DNW-A100P/A50P/A45P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dnw-a100pDnw-a50Dnw-a50pDnw-a45Dnw-a45p

Table of Contents