1. PRODUCT DESCRIPTION These operation and maintenance instructions apply to the DESMI ESLHT pump in /-17 execution. The ESLHT pump is designed for horizontal assembly with the pressure flange pointing upwards. The pump is a single-stage end suction centrifugal pump equipped with stainless steel shaft, balanced mechanical shaft seal mounted in a separate chamber with cooling ribs and fan cooling and closed impeller.
“calc” is the values calculated by the user. At the same time none of the forces or moments may exceed the indicated figure multiplied _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
The pump is to be stored in a dry area. Before shipment the pump is to be fastened securely on pallets or the like. The pump is to be lifted in the following way: _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
(48) the carbon bearing (4) 5.3 INSPECTION When the pump has been dismantled, check the following parts for wear and damage: _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com...
Page 10
Replace in case of wear and noise. - Sliding bearing/shaft : Wear= max. 0.5 mm diameter difference. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com...
10 revolutions - with water in the pump - but without adding pressure. Then pressure test the pump as normally done. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
Measured the coupling within the limits indicated in the below table. And tighten the set screw (37) after the coupling is in right position . _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
450 rpm and that a maximum of 1 minute is spent on acceleration from 0 to 450 rpm and 1 minute deceleration from 450 to 0 rpm. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
6. Pump and piping system Find the leakage, repair the fault, wrongly dimensioned non-return valve not submerged Check data sheet Q/H curve and NPSH or contact DESMI The pump uses too 1. Counter-pressure too low Insert orifice plate or check much power 2.
Loosen the point screw, then the sealing element itself can now be pulled off the shaft. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
10 g If the ball bearing is to be replaced, it is necessary to disassemble the pump and dismantle the pump shaft (as described in paragraph 5.1.3): _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
1.5 x the permissible working pressure. The test pressure is stated in the test certificate and stamped into the discharge flange of the pump. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø rresundby – Denmark...
14. EU DECLARATION OF CONFORMITY DESMI Pumping Technology A/S, hereby declare that our pumps of the ESLV and ESLH and ESLHT type are manufactured in conformity with the following essential safety and health requirements in the COUNCIL DIRECTIVE 2006/42/EC on machines, Annex 1.
No damage materials are used in DESMI pumps – please refer to DESMI Green Passport (can be sent on request – contact a DESMI sales office) – i.e. common recycling companies can handle the disposal at end-of-life. Alternatively the pump and motor can be returned to DESMI at end-of-life for safe recycling.
Cooling fan Support disc Air vent Sunk screw 17. DIMENSIONAL SKETCH Please require a dimensional sketch of the actual pump from DESMI. Connection holes on pump: Manometer: 1/4” BSP. Drain: 1/4” BSP. _______________________________________________________________________________ DESMI Pumping Technology A/S www.desmi.com Tagholm 1 9400 Nø...
Need help?