Contents 1. PRODUCT DESCRIPTION ........................... 4 1.1 DELIVERY ................................4 2. TECHNICAL DATA ............................... 4 2.1 ACCESSORIES ..............................4 2.2 SPACE AROUND THE PUMP ..........................4 2.3 EXPLANATION OF THE TYPE NUMBER ......................5 2.4 TECHNICAL DESCRIPTION ..........................6 3. INSTALLATION ..............................7 3.1 MOUNTING/FASTENING............................
Page 3
15. INFORMATION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END-OF-LIFE ......21 16. ASSEMBLY DRAWING ............................. 22 16.1 DSL300 SPACER DESIGN WITH BOTTOM ROLLER BEARING ............... 22 16.2 DSL300 COMPACT DESIGN WITH BOTTOM ROLLER BEARING ............24 16.3 DSL300 SPACER DESIGN WITH BOTTOM SLIDING BEARING ............... 26 16.4 DSL300 COMPACT DESIGN WITH BOTTOM SLIDING BEARING ............
The pumps are available in sizes ranging from 300 mm to 400 mm on the pressure flange. The suction flange is bigger than the pressure flange. The DESMI DSL-pump is a 1-stage centrifugal pump with stainless steel shaft, mechanical shaft seals and closed impeller of the double-suction type.
In case of doubt, contact the supplier. The pump is suitable for the pumping of liquids with temperatures up to 80° C. With special shaft seal ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
The capacity of the pump appears on the name plate of the pump. If the pump has been delivered without motor, the pump capacity is to be indicated on the plate when mounting the motor. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
At installations pumping hot or very cold liquids the operator must be aware that it is dangerous to touch the pump surface, and, consequently, he must take the necessary safety measures. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com www.desmi.com...
Press out the ceramic ring of the shaft seal (433.1) from the cover, and pull up the remaining components of the shaft seal. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com www.desmi.com...
Dismantle the rear cover, e.g. by means of a pulley drawer. Pull up the shaft with impeller. Follow item A. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com www.desmi.com...
When using oil or silicone grease on the shaft the bellows will settle and seat in about 15 minutes, and until then tightness should not be expected. After start, check for leaks by viewing the leak hole. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
7. When the coupling guard and the copper pipe to the rear cover have been fitted, and the procedure in paragraph 6.1 has been followed, the pump is ready for start. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
Together with a reading of the differential pressure the quantity of water delivered can be determined against ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
3. If the bearing has just been cleaned or if it is a new bearing, fill bearing completely and bearing housing approx. 1/3 with grease. 4. Use a recommended lithium-based grease, see the table below. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark Tel: +45 96 32 81 11 Fax: +45 98 17 54 99 E-mail: desmi@desmi.com www.desmi.com...
Page 17
On these pumps the bottom roller bearing shall be re-lubricated with 10 grams of grease every 5000 running hours through the external grease nipple mounted on the side of the pump casing. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
When ordering spare parts please always state pump type and serial No. See the name plate of the pump and the spare parts drawing with item Nos. See assembly drawing. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
1.5 x the permissible working pressure. The test pressure is stated in the test certificate and stamped into the discharge flange of the pump. ______________________________________________________________________________ DESMI Pumping Technology A/S Tagholm 1 9400 Nø rresundby – Denmark...
14. EU DECLARATION OF CONFORMITY DESMI PUMPING TECHNOLOGY A/S, hereby declare that our pumps of the type DSL are manufactured in conformity with the following essential safety and health requirements in the COUNCIL DIRECTIVE 2006/42/EC on machines, Annex 1. The following harmonized standards have been used: EN/ISO 13857:2008 Safety of machinery.
15. INFORMATION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END-OF-LIFE No damage materials are used in DESMI pumps – please refer to DESMI Green Passport (can be sent on request – contact a DESMI sales office) – i.e. common recycling companies can handle the disposal at end-of-life.