1. PRODUCT DESCRIPTION These operation and maintenance instructions apply to the DESMI Modular S-N super self-priming pump in type 02. The pump is available in three sizes, DN50, DN70 and DN80 on the pressure flange. The suction flange is bigger than the pressure flange.
The permissible loads on the flanges appear from the following table. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
The pump must be mounted in such a way that the shaft center line is horizontal. The max. permissible loads on the flanges stated in paragraph 2.3 are to be observed. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Page 6
When connecting the pump and a prime mover the power transmission is to be equipped with a guard in accordance with the provisions of the COUNCIL DIRECTIVE. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Before shipment the pump is to be fastened securely on pallets or the like. The pump is to be lifted as shown here: The lifting straps must not bear against sharp edges and corners. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Assemble the bearing cover and the shaft seal cover. Lead the water deflector over the shaft until it touches the shaft seal cover and then further 1-1.5 mm into the shaft seal cover DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
When the pump has been assembled, check that the shaft rotates freely. 6.9 FITTING COUPLING Mount coupling(19) to shaft(17) and let the coupling bear against the shoulder of shaft, and fix point screw(73). DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Pumps which are not in operation during frost periods are to be drained to avoid frost damage. Remove the plug in the inlet cover to empty the pump. Alternatively, it is possible to use anti-freeze liquids in normal constructions. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Together with a reading of the differential pressure the quantity of water delivered can be determined against the characteristics of the pump. DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11...
Page 12
1. Cavitation in pump Suction lift too high/ Suction line wrongly The pump makes noise dimensioned/Liquid temperature too high DESMI Pumping Technology A/S Tagholm 1 9400 Nørresundby - Denmark Tel.: +45 96 32 81 11 Fax +45 98 17 54 99 E-mail:...
(10.2 mWC = 1 bar) The powers stated in the table below are the highest possible absorbed by the pump, whereas the min./max. values for flow and pressure indicate DESMI's recommended operating range for the pump with the biggest impeller.
14. EC DECLARATION OF CONFORMITY DESMI PUMPING TECHNOLOGY A/S, hereby declare that our pumps of the type Modular S-N super self- priming pump in type 02 are manufactured in conformity with the following essential safety and health requirements in the COUNCIL DIRECTIVE 2006/42/EC on machines, Annex 1.
15. INFORMATION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END-OF-LIFE No damage materials are used in DESMI pumps – please refer to DESMI Green Passport (can be sent on request – contact a DESMI sales office) – i.e. common recycling companies can handle the disposal at end- of-life.