JAUDT SW GII 6406 Series Translation Of The Original Operating Instructions page 9

Distributor valves gii
Table of Contents

Advertisement

Operating manual SW GII 64006..., 6407..., 6408...
Distributor valve with inspection aperture opposite drive
In this version, the flap can be removed via the inspection aperture.
Run the system/silo empty or close the maintenance slide valve in front of the JAUDT distributor valve.
Secure the slide valve against being opened inadvertently.
Dismantle inspection aperture and limit switch, where necessary
Dismantle bearings opposite the drive
Remove the flap, check for wear and repair if necessary
Assemble flap, bearings and accessories in reverse order.
Check the movement of the flap and ensure correct sealing in the area of the flap/housing, bearings and
inspection aperture. Replace worn sealing elements if necessary.
Assemble inspection aperture
©SW_GII_EN_Rev02-2010.DOC