Operating manual SW GII 64006..., 6407..., 6408...
9
Faults
Fault
Flap squeaks or is sluggish
Leak at bolt of flap
Shaft encoder does not
transmit signals
Excessive current consumption
with electric servo drive
10
Cleaning
You must not use any cleaners containing acids or lyes.
11
Disposal
Waste oil and lubricants are classified as special waste. They must be disposed of in an environmentally
compatible manner in accordance with local regulations.
©SW_GII_EN_Rev02-2010.DOC
Cause
Gap too small due to
-
encrustation, moisture and
formation of rust
Gaskets / sealing ring cracked
-
Shaft encoder faulty
-
Switch cams loose
-
Flap / power transmission / drive
-
faulty
Foreign bodies in admission
-
Encrustation in housing
-
Gap too small
-
Remedy
Remove encrustation and rust,
-
enlarge gap
Renew gaskets / sealing rings
-
Renew
-
Adjust and tighten
-
Renew
-
Remove foreign bodies
-
Remove encrustation
-
Remove encrustation and rust,
-
enlarge gap
Page 13 of 15