Specifications; Generator Set - Generac Power Systems G0071450 Owner's Manual

Air-cooled generator sets
Table of Contents

Advertisement

Specifications

Generator Set

Model
Rated voltage
Alternate voltage
Rated maximum load
current (amps) at rated
voltage*
Maximum load current
(amps) at alternate
voltage*
Main line circuit breaker
Phase
Rated AC frequency
Battery requirement
Enclosure
Weight (kg / lb)
A-Weighted sound
pressure level (LpA)
Sound pressure
measurement uncertainty
A-Weighted sound power
level (LwA)
Sound power
measurement uncertainty
Normal operating range
These generator sets are rated in accordance with ISO 8528, Reciprocating Internal Combustion Engine Driven Alternating Current
Generating Sets–Safety.
* Natural gas ratings will depend on specific fuel joules / BTU content. Typical derates are between 10-20% off the LP gas rating.
Owner's Manual for 50 Hz Air-Cooled Generator Sets
8 kVA
36.4
34.8 / 33.3
40 A
Group 26R, 12 Volts and 540 CCA Minimum (See
154.7 / 341
75 dB(A)
94 dB(A)
This unit is tested in accordance to ISO 8528 standards with an operating temperature of -29 °C
(20 °F) to 50 °C (122 °F). For areas where temperatures fall below 0 °C (32 °F) a cold weather kit is
recommended. When operated above 25 °C (77 °F) there may be a decrease in engine power. Please
reference the engine specifications section.
10 kVA
220
230/240
45.5
43.5 / 41.7
50 A
1
50 Hz
Replacement
Aluminum
176.4 / 389
76 dB(A)
1 dB(A)
94 dB(A)
1 dB(A)
General Information
13 kVA
59.1
56.5 / 54.2
63 A
Parts)
192.8 / 425
77 dB(A)
95 dB(A)
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

G007189G007289

Table of Contents