Supermicro A+ Server AS -2014TP-HTR User Manual page 46

Table of Contents

Advertisement

A+ Server AS -2014TP-HTR User's Manual
Changing a System Fan
1. If necessary, open the chassis while the power is running to determine which fan has
failed. (Never run the server for an extended period of time with the chassis cover
open.)
2. Remove the failed fan's power cord from the backplane.
3. Lift the fan housing up and out of the chassis.
4. Push the fan up from the bottom and out of the top of the housing.
5. Place the replacement fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direction as the
arrows on the other fans.
6. Put the fan back into the chassis and reconnect the cable.
7. Confirm that the fan is working properly before replacing the chassis cover.
Figure 3-10. System Fan Placement
46

Advertisement

Table of Contents
loading

Table of Contents