Summary of Contents for Supermicro A+ Server AS -2014S-TR

  • Page 1 A+ Server AS -2014S-TR USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 About this Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ Server AS -2014S-TR. Installation and maintenance should be performed by experienced technicians only. Please refer to the AS -2014S-TR server specifications page on our website for updates on supported memory, processors and operating systems (http://www.supermicro.com).
  • Page 4: Table Of Contents

    Preface Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System ......................8 1.3 System Features ........................9 1.4 Server Chassis Features ....................10 Control Panel ........................10 Front Features ........................12 Drive Carrier Indicators ....................12 Rear Features ........................13 Power Supply Indicators ....................14 1.5 Motherboard Layout ......................15 Quick Reference Table ......................16 Chapter 2 Server Installation 2.1 Overview ..........................19...
  • Page 5 A+ Server AS -2014S-TR User's Manual Chapter 3 Maintenance and Component Installation 3.1 Removing Power ........................28 3.2 Accessing the System ......................29 Removing the Top Cover ....................29 3.3 Motherboard Components ....................30 Processor and Heatsink Installation ..................30 Memory Support ........................37 Memory Support ......................37 DIMM Module Population ....................38...
  • Page 6 Preface Chapter 5 Software 5.1 Microsoft Windows OS Installation ..................67 5.2 Driver Installation ........................69 5.3 SuperDoctor 5 ........................70 ® 5.4 BMC ............................71 BMC ADMIN User Password ....................71 Chapter 6 UEFI BIOS 6.1 Introduction .........................72 Starting the Setup Utility ....................72 6.2 Main Setup .........................73 6.3 Advanced ..........................75 6.4 IPMI ............................94 6.5 Event Logs .........................97...
  • Page 7 A+ Server AS -2014S-TR User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 8: Overview

    920W power supply PWS-920P-1R2 Notes: A Quick Reference Guide can be found on the product page of the Supermicro website. The following safety models associated with the AS -2014S-TR have been certified as compliant with UL or CSA: LA26-9 and LA26-R9H12.
  • Page 9: System Features

    Chapter 1: Introduction 1.3 System Features The following table provides you with an overview of the main features of the AS -2014S-TR. Please refer to Appendix C for additional specifications. System Features Motherboard H12SSL-i Chassis CSE-LA26TS-R920LPP Single AMD EPYC™ 7002/7003 Series Processor Socket Type Memory Eight DIMM slots to support up to 2TB of registered ECC DDR4-3200 SDRAM...
  • Page 10: Server Chassis Features

    A+ Server AS -2014S-TR User's Manual 1.4 Server Chassis Features Control Panel Power buttons and status LEDs are located on the control panel at the front of the chassis. The locations and descriptions of these buttons and LEDs are provided below. See Chapter 4 for details on the control panel connections.
  • Page 11 Chapter 1: Introduction Information LED Color, Status Description Red, solid An overheat condition has occurred. Red, blinking at 1Hz Fan failure, check for an inoperative fan. Red, blinking at 0.25Hz Power failure, check for a non-operational power supply. Red, solid, with Power LED blinking green Fault detected Blue and red, blinking at 10 Hz Recovery mode...
  • Page 12: Front Features

    A+ Server AS -2014S-TR User's Manual Front Features The CSE-LA26TS-R920LPP is a 2U chassis See the illustration below for the features included on the front of the chassis. Service/Asset Tag with BMC Password Control Panel Figure 1-2. System Front View...
  • Page 13: Rear Features

    Chapter 1: Introduction Rear Features The illustration below shows the features included on the rear of the chassis. The power supply modules also have status LEDs (see Chapter 3 for details). IPMI LAN Port UID LED PSU1 PSU0 VGA Port Drive Bays USB Ports LAN Ports...
  • Page 14: Power Supply Indicators

    Indicates that the power supply has a warning condition and continues to operate. Indicates that the power supply is plugged in, and is in an abnormal state. The Solid Amber system might need service. Please contact Supermicro technical support. No AC power to modules...
  • Page 15: Motherboard Layout

    Chapter 1: Introduction 1.5 Motherboard Layout Below is a layout of the H12SSL-i with jumper, connector and LED locations shown. See the table on the following pages for descriptions. For detailed descriptions, pinout information, and jumper settings, refer to Chapter 4. USB0/1 UID-SW LAN1...
  • Page 16: Quick Reference Table

    A+ Server AS -2014S-TR User's Manual Quick Reference Table Jumper Description Default Setting JBT1 Clear CMOS Open (Normal) JCFG1 JNVMe0/SATA0~7 switch Pins 1-2 (SATA) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN Enable/Disable Pins 1-2 (Enabled) JWD1 Watch Dog Control...
  • Page 17 Chapter 1: Introduction Connector Description USB 2/3 (3.0) Back panel USB 3.0 ports (USB 2/3) USB 4/5 (3.0) Internal USB 3.0 header (USB 4/5) Back panel VGA port...
  • Page 18 A+ Server AS -2014S-TR User's Manual SATA 8-15 G3 [0-7] NVMe 2-3 Slot 2 G3 [8-15] REVERSAL PCIe x8 SATA 0-7 G2 [0-7] NVMe 0-1 G2 [8-11] PCIe x4 M.2 REVERSAL G2 [12-15] PCIe x4 M.2 REVERSAL Slot 1 G1 [0-15]...
  • Page 19: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components. Caution: Electrostatic Discharge (ESD) can damage electronic components.
  • Page 20: Rack Precautions

    A+ Server AS -2014S-TR User's Manual Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them. • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together.
  • Page 21: Mechanical Loading

    Chapter 2: Server Installation Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring.
  • Page 22: Installing The Rails

    A+ Server AS -2014S-TR User's Manual 2.3 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. This rail set fits a rack between 26.8" and 36.4" deep. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided.
  • Page 23: Releasing The Inner Rail

    Chapter 2: Server Installation Releasing the Inner Rail Each inner rail has a locking latch. This latch prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing. To mount the rail onto the chassis, first release the inner rail from the outer rails. Releasing Inner Rail from the Outer Rails 1.
  • Page 24: Installing The Inner Rails On The Chassis

    A+ Server AS -2014S-TR User's Manual Installing the Inner Rails on the Chassis Installing the Inner Rails 1. Identify the left and right inner rails. They are labeled. 2. Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
  • Page 25: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail. 3. Hang the hooks on the front of the outer rail onto the square holes on the front of the rack.
  • Page 26: Installing The Server Into The Rack

    A+ Server AS -2014S-TR User's Manual 2.4 Installing the Server into the Rack Once rails are attached to the chassis and the rack, you can install the server. 1. Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail.
  • Page 27: Removing The Chassis From The Rack

    Chapter 2: Server Installation Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack.
  • Page 28: Chapter 3 Maintenance And Component Installation

    A+ Server AS -2014S-TR User's Manual Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 29: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The system features a removable top cover, which allows access to the inside of the system. Removing the Top Cover 1. Press the two release buttons and slide the cover toward the rear. 2.
  • Page 30: Motherboard Components

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the Processor and Heatsink 1. Unscrew the screws holding down Force Frame in the sequence of 3-2-1. The screws are numbered on the force frame next to each screw hole.
  • Page 31 Chapter 3: Maintenance and Component Installation 2. The spring-loaded force frame will raise up after the last screw securing it (#1) is removed. Gently allow it to lift up to its stopping position. 3. Lift the rail frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the rail frame, lift it to a position so you can do the next step of removing the external cap.
  • Page 32 A+ Server AS -2014S-TR User's Manual 4. Remove the external cap from the Rail Frame by pulling it upwards through the rail guides on the rail frame. External Cap PnP Cover Cap 5. The CPU package is shipped from the factory with the blue carrier frame pre-assembled.
  • Page 33 Chapter 3: Maintenance and Component Installation Note: You can only install the CPU inside the socket in one direction with the handle at the top. Make sure that it is properly inserted into the CPU socket before closing the rail frame plate.
  • Page 34 A+ Server AS -2014S-TR User's Manual 9. Gently lower the force frame down onto the rail frame and hold it in place until it is seated in the Socket housing. Note that the force frame is spring loaded and has to be held in place before it is secured.
  • Page 35 Chapter 3: Maintenance and Component Installation 11. After the force frame is secured and the CPU package is in place, now you must install the heatsink to the frame. Lower the heatsink down till it rests securely over the four screw holes on CPU package on the socket frame.
  • Page 36 A+ Server AS -2014S-TR User's Manual Un-installing the Processor and Heatsink 1. Remove the heatsink attached to the top of the CPU package by reversing the installation procedure. 2. Clean the Thermal grease left by the heatsink on the CPU package lid to limit the risk of it contaminating the CPU package land pads or contacts in the socket housing.
  • Page 37: Memory Support

    Chapter 3: Maintenance and Component Installation Memory Support Note: Check the Supermicro website for recommended memory modules. Important: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The H12SSL-i supports Up to 2TB of registered ECC DDR4-3200 SDRAM in eight slots.
  • Page 38: Dimm Module Population

    A+ Server AS -2014S-TR User's Manual DIMM Module Population When installing memory, please keep the following in mind: • It is recommended that DDR4 DIMM modules of the same type, size and speed should be installed. • Mixed DIMM speeds can be installed. However, all DIMMs will run at the speed of the slowest DIMM.
  • Page 39: Dimm Installation

    Chapter 3: Maintenance and Component Installation DIMM Installation JCOM1 UID-SW JRU1 JWD1 JUID1 JVRM1 JUART1 COM1 USB0/1 (3.0) JDBG1 JTPM2 1. Follow the instructions given in the IPMI_LAN JIPMB1 memory population guidelines listed in LEDM1 BMC_HB JRWIO1 the previous sections to install memory modules on your motherboard.
  • Page 40: Pci Expansion Cards

    A+ Server AS -2014S-TR User's Manual PCI Expansion Cards The system can accommodate up to seven low-profile PCIe 4.0 expansion cards. Figure 3-3. Expansion Card Slots Expansion Slot Descriptions Item Description PCIe 4.0 x16 (low-profile) PCIe 4.0 x8 (low-profile) PCIe 4.0 x16 (low-profile) PCIe 4.0 x8 (low-profile)
  • Page 41: Installing Expansion Cards

    Chapter 3: Maintenance and Component Installation Installing Expansion Cards 1. Power down the system and remove the top cover. 2. In the rear of the chassis, remove the blank PCI shield that covers the expansion slot to be populated. 3. Install the expansion card making sure it is firmly seated in the slot, then secure it to the chassis with a screw, as shown below.
  • Page 42: Motherboard Battery

    A+ Server AS -2014S-TR User's Manual Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in section 3.1.
  • Page 43: Chassis Components

    NVMe or SAS/SATA drives. Drive carrier status indicators are described in Section 1.2 Note: Enterprise level hard disk drives are recommended for use in Supermicro servers. For compatible storage drives, see the H12SSL-i motherboard web page.
  • Page 44 A+ Server AS -2014S-TR User's Manual Removing a Hot-Swap Drive Carrier from the System 1. Press the release button on the drive carrier, which will extend the drive carrier handle. 2. Use the drive carrier handle to pull the drive out of the chassis.
  • Page 45 Chapter 3: Maintenance and Component Installation Installing a 3.5" Drive 1. Remove the dummy drive, which comes pre-installed in the drive carrier. Pull out the two locking clasps on the right outside of the carrier and lift out the dummy drive. 2.
  • Page 46 A+ Server AS -2014S-TR User's Manual Insert this side second Figure 3-9. Installing a 3.5" Drive into a Carrier Installing a 2.5" Drive 1. Remove the dummy drive, which comes pre-installed in the drive carrier. Pull out the two locking clasps on the left outside of the carrier and lift out the dummy drive.
  • Page 47: Hot-Swap For Nvme Drives

    Chapter 3: Maintenance and Component Installation Hot-Swap for NVMe Drives Supermicro Ultra servers support NVMe surprise hot-swap. For even better data security, NVMe orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely using IPMI. Note: If you are using VROC, see the VROC appendix in this manual instead.
  • Page 48: System Cooling

    A+ Server AS -2014S-TR User's Manual System Cooling Three 4-cm fans provide the cooling for the system. Make sure the chassis top cover makes a good seal so the cooling air circulates properly through the chassis Changing a System Fan 1.
  • Page 49: Checking The Server Air Flow

    Some backplanes allow the overheat temperature to be set at 45, 50, or 55 degrees by changing a jumper setting. For more information, consult the backplane user manual at www. supermicro.com. (Click Support, then the Manuals link.) Responses If the server overheats: 1.
  • Page 50: Power Supply

    Power Supply The chassis features redundant power supplies. The power modules can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are auto-switching capable. This feature enables them to automatically sense the input voltage and operate at a 100-120v or 180-240v.
  • Page 51 Chapter 3: Maintenance and Component Installation Release Tab Handle A(2:1) Figure 3-13. Installing a Power Supply Module...
  • Page 52: Power Connections

    A+ Server AS -2014S-TR User's Manual Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
  • Page 53: Headers And Connectors

    Chapter 4: Motherboard Connections 12V 8-pin Auxilliary Power Connector (JPWR1) JPWR1 is an 8-pin ATX power input to provide core power to the processor. Refer to the table below for pin definitions. 12V 8-pin Power Connector Pin Definitions Pins Definition 1 through 4 Ground 5 through 8...
  • Page 54 A+ Server AS -2014S-TR User's Manual Disk-On-Module Power Connector (JSD1 & JSD2) The Disk-On-Module (DOM) power connector at JSD1 provides 5V power to a solid-state DOM storage device connected to one of the SATA ports. See the table below for pin definitions.
  • Page 55 It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Please go to the following link for more information on TPM: http://www.supermicro.com/ manuals/other/TPM.pdf. Trusted Platform Module Header...
  • Page 56 A+ Server AS -2014S-TR User's Manual USB Ports (USB0~USB5) There are a total of six USB ports supported on the motherboard. Four are located on the back panel (USB 0/1 (3.0) and USB 2/3 (3.0)). There are also two ports located on the motherboard header (USB 4/5 (3.0)).
  • Page 57 Chapter 4: Motherboard Connections Standby Power Header (JSTBY1) The Standby Power header is located at JSTBY1 on the motherboard. Standby Power Pin Definition Pins Definition +5V Standby Ground Wake-up IPMB System Management Bus Header (JIPMB1) A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I C connection on your system.
  • Page 58: Control Panel

    A+ Server AS -2014S-TR User's Manual Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 59 Chapter 4: Motherboard Connections Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach the hardware reset switch from the computer case to this header to reset the system. Refer to the table below for pin definitions.
  • Page 60 A+ Server AS -2014S-TR User's Manual HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a hard drive LED cable here to display disk activity detected on the motherboard's built-in disk controllers. See the table below for pin definitions.
  • Page 61: Ports

    Chapter 4: Motherboard Connections 4.3 Ports Rear I/O Ports See the figure below for the locations and descriptions of the various I/O ports on the rear of the motherboard. Figure 4-2. Rear I/O Ports Rear I/O Ports Description Description Description COM Port USB 1 (3.0) LAN Port #1...
  • Page 62 A+ Server AS -2014S-TR User's Manual VGA Port There is one VGA port on the rear I/O panel. UID Switch and LED Indicator A Unit Identifier (UID) switch and UID LED are located on the I/O backpanel. The rear UID LED is located next to the UID switch.
  • Page 63: Jumpers

    Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 64 A+ Server AS -2014S-TR User's Manual Watch Dog JWD1 controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs.
  • Page 65: Led Indicators

    Chapter 4: Motherboard Connections 4.5 LED Indicators LAN Port LEDs The motherboard's Ethernet ports has one LED indicators. The Activity LED is green and indicates connection and activity. The Link LED may be green, orange/amber, or off to indicate the speed of the connection. Refer to the tables below for more information. Link LED Activity LED Connection Link Speed Indicator...
  • Page 66 A+ Server AS -2014S-TR User's Manual Onboard Power OK LED (LE1) LE1 is an onboard power OK LED. When this LE1 is lit, it means the system is turned on, and all the system power rails are ready. When the system is turned off, or any one of the system power rails fail, this LED will turn off.
  • Page 67: Chapter 5 Software

    USB/SATA DVD drive, or a USB flash drive, or the IPMI KVM console. 2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 68 A+ Server AS -2014S-TR User's Manual 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner.
  • Page 69: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to to a USB flash drive or a DVD.
  • Page 70: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 71: Bmc

    There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: www.supermicro.com/en/solutions/management-software/bmc-resources BMC ADMIN User Password For security, each system is assigned a unique default BMC password for the ADMIN user.
  • Page 72: Chapter 6 Uefi Bios

    A+ Server AS -2014S-TR User's Manual Chapter 6 UEFI BIOS 6.1 Introduction This chapter describes the AMIBIOS™ Setup utility for H12SSL-i motherboards that are equipped with the Single AMD EPYC™ 7002/7003 Series Processor. The BIOS is stored on a chip and can be easily upgraded using a flash program.
  • Page 73: Main Setup

    Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2015 after RTC reset. Supermicro H12SSL-i BIOS Version This item displays the version of the BIOS ROM used in the system.
  • Page 74 A+ Server AS -2014S-TR User's Manual Build Date This item displays the date when the version of the BIOS ROM used in the system was built. CPLD Version This item displays the CPLD version of the BIOS ROM used in the system.
  • Page 75: Advanced

    Chapter 6: UEFI BIOS 6.3 Advanced Use the arrow keys to select a top item and press <Enter> to access the submenu items. Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable.
  • Page 76 A+ Server AS -2014S-TR User's Manual Bootup NumLock State Use this feature to set the Power on state for the <Numlock> key. The options are On and Off. Wait For "F1" If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs.
  • Page 77 Chapter 6: UEFI BIOS Trusted Computing Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM (Trusted Platform Module) support to enhance data integrity and network security. Please reboot the system for a change on this setting to take effect.
  • Page 78 A+ Server AS -2014S-TR User's Manual ACPI SRAT L3 Cache As NUMA Domain Use this setting to enabe/disable ACPI SRAT L3 Cache As NUMA Domain. The options are Disabled, Enabled, and Auto. Super IO Configuration The following Super IO information will display: •...
  • Page 79 Chapter 6: UEFI BIOS Serial Port Console Redirection COM1 Console Redirection Select Enabled to enable console redirection support for a serial port specified by the user. The options are Disabled and Enabled. *If the item above set to Enabled, the following items will become available for user's configuration: Console Redirection Settings Terminal Type...
  • Page 80 A+ Server AS -2014S-TR User's Manual Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
  • Page 81 Chapter 6: UEFI BIOS *If the item above set to Enabled, the following items will become available for user's configuration: Console Redirection Settings Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support.
  • Page 82 A+ Server AS -2014S-TR User's Manual VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled. Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server.
  • Page 83 Chapter 6: UEFI BIOS Console Redirection Settings Out-of-Band Mgmt Port The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote host server. The options are COM1 and SOL. Terminal Type Use this feature to select the target terminal emulation type for Console Redirection.
  • Page 84 A+ Server AS -2014S-TR User's Manual CPU Configuration SMT Control Use this setting to specify Simultaneous Multithreading. The options are Disabled and Auto. Core Performance Boost This setting is used to configure for Core Performance Boost. Options include Disabled and Auto.
  • Page 85 Chapter 6: UEFI BIOS CPU1 Information These sections are for informational purposes. They will display some details about the detected CPUs on the motherboard, such as: • CPU Version • Number of Cores Running • Processor Family • Processor Model •...
  • Page 86 A+ Server AS -2014S-TR User's Manual Memory Configuration Memory Clock This setting allows you to select different memory clock speed. Options include Auto and supported frequencies. Memory Interleaving This setting controls fabric level memory interleaving. Note that the channel, die and socket have requirements on memory populations and it will be ignored if the memory doesn't support the selected option.
  • Page 87 Chapter 6: UEFI BIOS SR-IOV Support If the system has SR-IOV capable PCIe devices, this setting will Disable or Enable the Single Root IO Virtualization Support for the system. BME DMA Mitigatioin Use this setting to re-enable the Bus Master Attribute that was disabled during PCI enumeration for PCI bridges after SMM is locked.
  • Page 88 A+ Server AS -2014S-TR User's Manual CPU SLOT 5 PCI-E 4.0 X16 OPROM This setting enables or disables the listed PCI/PCIX/PCIe Slot OPROM option. The options include Disabled, Legacy and EFI. CPU SLOT 6 PCI-E 4.0 X16 OPROM This setting enables or disables the listed PCI/PCIX/PCIe Slot OPROM option. The options include Disabled, Legacy and EFI.
  • Page 89 Chapter 6: UEFI BIOS CPU SLOT4 PCI-E 4.0 X8 Bifurcation This setting selects the bifurcation configuration for this particular PCIe slot. The options include Auto, and x4x4. CPU SLOT5 PCI-E 4.0 X16 Bifurcation This setting selects the bifurcation configuration for this particular PCIe slot. The options include Auto, x16, x8x8, x4x4x8, and x4x4x4x4.
  • Page 90 A+ Server AS -2014S-TR User's Manual IPv6 HTTP Support This setting allows you to Disable or Enable IPv6 HTTP boot support. If disabled, IPv6 HTTP boot support will not be available. PXE Boot Wait Time This setting allows you to set in a number field the wait time to press the ESC key to abort the PXE boot.
  • Page 91 Chapter 6: UEFI BIOS SATA Information This section displays information on the detected SATA devices: • I-SATA0~7 • SATA0~15 KMIP Server Configuration This feature allows the user to adjust KMIP Server network parameters. KMIP Server IP address KMIP TCP Port number TimeZone Client UserName Client Password...
  • Page 92 A+ Server AS -2014S-TR User's Manual Network Configuration Configured Select Enabled to activate IPv4 network configuration. The options are Enabled and Disabled. *If the item above is set to Enabled, the following item will become available for configuration: Enable DHCP This feature allows the user to select the source of the IP address for this computer.
  • Page 93 Chapter 6: UEFI BIOS Add an Attempt Delete Attempts Change Attempt Order TLS Authenticate Configuration This submenu allows the user to configure Transport Layer Security (TLS) settings. Server CA Configuration Enroll Certification Enroll Certification using File Use this feature to enroll certification from a file. Certification GUID Use this feature to input the certification GUID.
  • Page 94: Ipmi

    A+ Server AS -2014S-TR User's Manual 6.4 IPMI This tab allows you to configure the following IPMI settings for the system. Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. BMC Firmware Revision This item indicates the IPMI firmware revision used in your system.
  • Page 95 Chapter 6: UEFI BIOS Erasing Settings Erase SEL Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot.
  • Page 96 A+ Server AS -2014S-TR User's Manual Station IP Address This item displays the Station IP address for this computer. This should be in decimal and in dotted quad form. Subnet Mask This item displays the sub-network that this computer belongs to. The value of each three- digit number separated by dots should not exceed 255.
  • Page 97: Event Logs

    Chapter 6: UEFI BIOS 6.5 Event Logs This tab allows the user to configure the following event logs settings for the system. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot. The options are Disabled and Enabled. Erasing Settings Erase Event Log Select Yes to erase all error events in the SMBIOS (System Management BIOS) log before...
  • Page 98 A+ Server AS -2014S-TR User's Manual When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full.
  • Page 99: Security

    Chapter 6: UEFI BIOS 6.6 Security This tab allows you to configure the following security settings for the system. Administrator Password Press Enter to create a new, or change an existing Administrator password. Note that if the Administrator Password is erased, the User Password will be cleared as well. Password Check Select Setup for the system to check for a password at Setup.
  • Page 100 A+ Server AS -2014S-TR User's Manual SMCI Security Erase Configuration Secure Boot This section contains options and menus for securing your boot mode and for key management. Secure Boot This option allows you specify when the Platform Key (PK) is enrolled. When enabled, the System Mode is user deployed, and the CSM function is disabled.
  • Page 101 Chapter 6: UEFI BIOS Device Guard Ready Remove 'UEFI CA' from DB B (available when the system is not in Device Guard Ready) Select and press Yes to remove Microsoft UEFI CA certificate from the DB. The options are Yes and No. Restore DB defaults Select and press Yes to restore the DB variables to factory defaults.
  • Page 102 A+ Server AS -2014S-TR User's Manual Append Key Select Yes to add the DBX from the manufacturer's defaults to the existing DBX. Select No to load the DBX from a file. The options are Yes and No. Authorized TimeStamps Set New Key Select Yes to load the DBT from the manufacturer's defaults.
  • Page 103: Boot

    Chapter 6: UEFI BIOS 6.7 Boot Use this tab to configure Boot Settings: Boot Mode Select Use this item to select the type of device that the system is going to boot from. The options are Legacy, UEFI, and DUAL. The default setting is DUAL. LEGACY to EFI Support This option Disables or Enables the system to boot to an EFI OS after the boot failed from the legacy boot order.
  • Page 104 A+ Server AS -2014S-TR User's Manual Delete Boot Option Use this feature to remove a pre-defined boot device from which the system will boot during startup. The settings are [any pre-defined boot device]. UEFI Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices.
  • Page 105: Save & Exit

    Chapter 6: UEFI BIOS 6.8 Save & Exit Select the Save & Exit tab to enter the Save & Exit BIOS Setup screen. Save Options Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer.
  • Page 106 A+ Server AS -2014S-TR User's Manual Discard Changes Select this option and press <Enter> to discard all the changes and return to the AMI BIOS utility Program. Default Options Restore Optimized Defaults To set this feature, select Restore Optimized Defaults from the Save & Exit menu and press <Enter>.
  • Page 107: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 108 Appendix A: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 109 A+ Server AS -2014S-TR User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬...
  • Page 110 Appendix A: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 111 A+ Server AS -2014S-TR User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 112 Appendix A: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 113 A+ Server AS -2014S-TR User's Manual ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬...
  • Page 114 Appendix A: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 115 A+ Server AS -2014S-TR User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial,...
  • Page 116 Appendix A: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 117 A+ Server AS -2014S-TR User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가...
  • Page 118 Appendix A: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 119 A+ Server AS -2014S-TR User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 120 Appendix A: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 121 A+ Server AS -2014S-TR User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다.
  • Page 122 Appendix A: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 123 A+ Server AS -2014S-TR User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 124 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 125 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 126 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 127: Appendix B Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 128 A+ Server AS -2014S-TR User's Manual Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB flash device and rename it "Super.ROM". 2. While the system is turned off, insert the USB device that contains the new BIOS binary image (SUPER.ROM).
  • Page 129 • SUPERMICO BIOS Update: https://www.youtube.com/watch?v=S8z6iOEHGwY • If the BIOS flash recovery fails, contact our RMA Department to have the BIOS chip reprogrammed. This will require shipping the board to Supermicro for repair. • Submit your RMA request at https://www.supermicro.com/support/rma •...
  • Page 130: Appendix C System Specifications

    A+ Server AS -2014S-TR User's Manual Appendix C System Specifications Processor Support Single AMD EPYC™ 7002/7003 Series Processor in an SP3 type socket Notes: Please refer to the motherboard specifications pages on our website for updates to supported processors. Chipset...
  • Page 131 Appendix C: System Specifications Regulatory Compliance FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB Applied Directives, Standards EMC/EMI: 2014/30/EU (EMC Directive) Electromagnetic Compatibility Regulations 2016 FCC Part 15 Subpart B ICES-003 VCCI-CISPR 32 AS/NZS CISPR 32 BS/EN 55032 BS/EN 55035 CISPR 32 CISPR 35 BS/EN 61000-3-2...